T e c h n i c a l S p e c if ic a t i o n s
PDP4225M
1. S ta n d a rd T e s t C o n d itio n s
All tests shall be performed under the following conditions, unless otherwise specified.
1.1
Ambient light
: 150ux (When measuring IB, the ambient luminance
= 0.1Cd/m2)
1.2
Viewing distance
: 50cm in front of PDP
1.3
Warm up time
: 30 minutes
1.4
PDP Panel facing
: no restricted
1.5
Measuring Equipment
: PC, Chroma 2225 signal generator (with Chroma digital
additional card) or equivalent, Minolta CA100 photometer
1.6
Magnetic field
: no restricted
1.7
Control settings
: Brightness, Contrast, Tint, Color set at Center(50)
1.8
Power input
: 100~120Vac 60Hz
1.9
Ambient temperature
: 20°C ± 5°C (68°F ± 9°F)
1.10
Display mode
: Resolution 1024 (H) x 1024 (V) Pixels
1.11
Other conditions
1.11.1 With image sticking protection of PDP module, the luminance will descend
by time on a same still screen and rapidly go down in 5 minutes. When
measuring the color tracking and luminance of a same still screen, be sure t
o accomplish the measurement in one minute to ensure its accuracy.
1.11.2 Due to the structure of PDP, the extra-high-bright same screen should not
hold over 5 minutes for fear of branding on the panel.
3/73