SENDING MIDI SYSEX SONG AND PATTERN DATA TO THE XR20
If you wish to load Pattern and Song data back into the XR20, please follow the instructions
below. Please note that this operation will erase any Song and Pattern data which exists on the
XR20!
1. Connect a 5-pin MIDI cable from your MIDI SysEx device to the XR20’s MIDI IN.
2. Turn off the XR20.
3. Hold down the SAVE / COPY button.
4. Turn on the XR20 while holding down the
SAVE / COPY button.
5. After a few seconds, you should see the
screen displayed on the right. The XR20 is
ready to receive data.
6. Now transfer the MIDI system exclusive data
into the XR20. Refer to your MIDI SysEx
device’s documentation for information on
transferring MIDI SysEx.
7. Once the transfer is complete, turn off the
XR20 and then turn it back on.