O
C
room temperature (TA)
TS+1
TS
Electric heater OFF
Temp down
Temp up
Electric heater ON
than 10
o
C or 48
o
F, the display will be 10
o
C or
48
o
F.
2.2.10 Timer Function
O
C
room temperature (TA)
13 C
o
Compressor and outdoor
fan ON
Temp down
Temp up
Compressor and
outdoor fan OFF
15 C
o
O
C
room temperature (TA)
TS+1
TS
Compressor ON
Temp down
Temp up
Compressor OFF
8
Model No.: AC-PR12HM
Version: 1.0
¾ When the water adds up to the position on the tank, the compressor, outdoor fan
motor, electric heater and pump will stop operation. And the LED will display “P1”
while the water full lamp flashes at 2Hz.
¾ When the water adds up to the second position on the chassis and the switch has been
on for 10 seconds, the whole unit will stop operation. The LED will display “P2” and
the water full lamp will flash at 5Hz. After you have clear the problem, you should
unplug the unit and plug again. Then the unit will be ready to operate.
¾ When the unit is standing by, if the unit displays “P1”, the pump will not operate.
After the problem is cleared, the unit will be ready to operate. But if you push the
power button, the unit will shut the “P1” display and shut down.
e. Fan-only Mode Function Requirement
i. The compressor and outdoor fan are OFF at Fan-only mode.
ii. The speed of indoor fan can be optionally chosen as High/Mid/Low.
f. Cooling Mode Function Requirement
i. The speed of indoor fan can be optionally selected as High/Mid/Low.
ii. The compressor operate as:
g. Drying mode
i. When the unit starts to operate in Drying mode, the compressor will start while the room
temperature is over 13oC. After the compressor started, the compressor will operate as:
ii. The indoor fan will operate with high speed. The outdoor fan will operate with compressor.
h. Heating mode
i. The speed of indoor fan can be optionally chosen as High/Mid/Low.
ii. Electric heater operate as :