EasyManua.ls Logo

akira ac-s13 - Page 16

akira ac-s13
56 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
16
Model No:AC -S13CK_S13HK
Version 1.0
l The indoor fan motor speed will be controlled as following. (for 24K heat pump)
7. SMART MODE OPERATION
l When SMART air conditioning is selected, the operation mode and preset
temperature are set automatically according to the room temperature at starting
operation.
l The operation procedure of cooling only is as following.
Intake air temperature at
operation start
Over 26
o
C Below 26
o
C
Preset temperature
26
o
C
Intake air temperature minus
1.5
o
C
Operation mode COOLING DRY
*The initial mode will be continued and independent upon the room temperature
changing.
l The operation procedure of heat pump is as following.