SUGGESTED NOZZLE TIP SIZE
TYPICAL PUMPER TESTS* (LPM)
2000 LPM PUMPER
100% rated capacity 1000 38.1 440 2018
70% rated capacity 1350 28.5 680 1401
50% rated capacity 1700 28.5 350 1003
3000 LPM PUMPER
100% rated capacity 1000 50.8 320 3051
70% rated capacity 1350 38.1 480 2112
50% rated capacity 1700 28.5 790 1518
4000 LPM PUMPER
100% rated capacity 1000 50.8 550 4024
70% rated capacity 1350 44.5 470 2839
50% rated capacity 1700 38.1 440 2018
5000 LPM PUMPER
100% rated capacity 1000 57.2 540 5035
70% rated capacity 1350 50.8 430 3543
50% rated capacity 1700 38.1 690 2525
6000 LPM PUMPER
100% rated capacity 1000 57.2 790 6113
70% rated capacity 1350 50.8 610 4221
50% rated capacity 1700 44.5 540 3040
7000 LPM PUMPER
100% rated capacity 1000 50.8 2 lines 430 3543
100% rated capacity 1350 44.5 2 lines 730 3528
70% rated capacity 1350 57.2 510 4906
50% rated capacity 1700 50.8 430 3543
8000 LPM PUMPER
100% rated capacity 1000 50.8 2 lines 550 4024
70% rated capacity 1350 44.5 2 lines 730 3528
70% rated capacity 1350 57.2 680 5644
50% rated capacity 1700 50.8 550 4024
* Based on Test Requirements “ULC-822 Guide for Listing and Labeling of
Fire Department Pumpers” Underwriters Laboratories of Canada, Scarborough,
Ontario, Canada
Figures represented on the Discharge Table are accurate to ±3% at tested values in accordance with the
classification scope.
NET NOZZLE PITOT
PUMP TIP PRESSURE
PRESSURE SIZE-MM KPA GPM