1.3 SITE REQUIREMENTS
Usually the Cabinets will be fixed to existing walls in the positions determined by the Site
Survey.
Do not mount the 4080 IP-DECT to a metal wall!
1.4 TEMPERATURE RANGES
Temperature range 4080 IP-DECT: -5° to 45° C.
The AP400 should not be exposed to sunlight!
The outside temperature range for the 4080 IP-DECT (all types) mounted in the Outdoor
Cabinet is as follows:
Minimum outside temperature: -20° C
Maximum outside temperature: 45° C
The Outdoor Cabinet should not be exposed to sunlight!
1.5 CABLE SPECIFICATIONS FOR 4080 IP-DECT Types
The cabling to the 4080 IP-DECT(External antennas) is “Category 5” or “Category 6”
Ethernet cabling. The interface is defined as an SELV interface according EN60950-1.
For this reason the following safety restriction is applicable:
Caution: The cabling and/or the 4080 IP-DECT(External antennas) may never be
exposed to over-voltages (e.g. lightning). Therefore, the 4080 IP-
DECT(External antennas) and cabling associated with it may never be
installed outdoors! However there is an exception: if installed in the Outdoor
Cabinet, and the Outdoor Cabinet is mounted against a wall and
the cable is
led directly indoors, it is permitted. For details about this specific installation
refer to the installation manual of the Outdoor Cabinet.
Note: Cat 7 cabling is not supported!