• The exhaust ue hose must not come
into contact with fuel lines, water hoses,
plastic pipes or electrical cables.
• The exhaust ue hose must not be
integrated into any other exhaust or outlet
on the craft.
5:6 Fitting the air intake/ue exhaust
hose
Only instructions regarding the roof
mounted ue is applicable.
5:7 Fitting the expansion tank
The drain hose (Figure F 18) has to be
tted so that it fol lows the shortest route
from the expansion tank and out through
the oor of the vehicle. Cut the hose obli-
quely under the vehicle at an angle of 30°
facing the rear of the vehicle (Figure G).
Is replaced by the following:
“The drain hose must be tted so that it fol-
lows the shortest route from the expansion
tank to a suitable secure container or bilge.”
5:8 Connection to the heating system
The drain hose from the bleeder (Figure
H 23) must be routed through the oor of
the vehicle. Cut the hose obliquely at an
angle of 30° facing the rear of the vehicle
(Figure G).
Is replaced by the following:
“The drain hose must be tted so that it fol-
lows the shortest route from the expansion
tank to a suitable secure container or bilge”
5:9 Connection to the water system
As it is stated.
5:10 Installation of safety/drain valve
oor” is replaced by the following: “suita-
ble secure container or bilge”.
5:11 LPG connection
• The LPG installation to the boiler has
to be executed using 8 mm copper or ste-
el pipe, and be connected to the boiler’s
gas pipe with a compression coupling.
When routing pipes, bear in mind that all
joints/couplings have to be easily acces-
sible and it has to be possible to disas-
semble the boiler for servicing.
• The LPG connection to the boiler must
have a separate shut-o tap that is easily
accessible.
• The boiler must be connected to an LPG
cylinder with a type-approved reducing
valve with a pressure of 30 mbar.
For increased safety, we recommend tting
an Alde leak detector, type 4071, as close
as possible to the reducing regulator.”
Is replaced by the following:
The LPG installation to the boiler must
be executed using regulation 8 mm cop-
per, stainless steel or cupronickel pipe,
and be connected to the boiler’s gas pipe
with a compression or cutting-ring com-
pression tting. When routing pipes, bear
in mind that all joints/couplings must be
easily accessible, and it must be possible
to conveniently service the boiler.
The LPG connection to the boiler must
have a separate shut-o valve that is
easily accessible. It is recommended to t
a gas test point on the gas pipe as close
to the boiler as possible.
The boiler must be connected to an LPG
cylinder with a type-approved dual-fuel re-
gulator with a nominal operating pressure
of 30 mbar.
5:12 Electrical connection
The boiler must be connected perma-
nently to a 230 VAC supply and be pro-
tected with a 10 A fuse for a 2 kW.
Is replaced by the following:
The boiler must be permanently connec-
ted to 230 VAC supply and be protected
by a 16 A MCB and RCD. It is recommen-

Other manuals for Alde Compact 3020 HE

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Alde Compact 3020 HE and is the answer not in the manual?

Alde Compact 3020 HE Specifications

General IconGeneral
BrandAlde
ModelCompact 3020 HE
CategoryBoiler
LanguageEnglish

Related product manuals