The generator should also be located in an open area with fresh air and
NOT in a conned area.
WARNING: Ensure the engine is switched o while undertaking
this task.
1. Remove the fuel tank cap (27) by rotating in an anticlockwise direction.
2. Remove the fuel tank inlet lter (24) and ensure it is clean and free of
debris. Check the level of fuel is sucient.
3. If the fuel tank inlet lter (24) was removed to check the fuel level, ensure
it is replaced back before adding fuel.
4. To add fuel, pour the unleaded fuel from an approved fuel container
into the fuel tank (26). As fuel expands, DO NOT FILL to the lip of the tank.
Maximum ll is to the top of the fuel tank inlet lter (24) rim.
5. Replace fuel tank cap (27) turning in a clockwise direction to lock.
Filling and checking the Engine oil
The engine of this generator is NOT lled with oil when unpacked. Prior to
starting the engine ensure the oil tank is lled with SAE 10W-30 4 stroke oil.
For the rst time ll the engine should be lled with 400ml of SAE 10W-30
oil.
NOTE: Damage to the engine is not covered under warranty if the engine
is run with insucient oil.
NOTE: Ensure the fuel tank cap (27) is secure before attempting to add oil.
1. Before checking or relling oil, be sure the generator is put on a
stable and level surface, ensuring the engine has been switched
OFF. When lling with oil you can lift the generator approximately
100mm at the front (Fig D), however the
generator must be sitting at back on its
feet when checking the level of oil using
the oil ller cap/dipstick (12).
Make sure you check the capacity of fuel
tank before checking the oil level. The
fuel tank (26) should be less than 50% full
when the generator is tilted by 100mm to
ll the oil reservoir, or fully drained if the
generator is tilted more than 100mm.