AA.
AB.
AC
.
AD.
Storage and Transportation
Fuel Tank Inlet Filter
WARNING: Ensure the engine is switched o while undertaking
this task.
1. Turn the fuel tap/ lever (23) to the o position (Fig AA).
2. The fuel tank inlet lter (24) is located directly under the fuel tank cap
(27) and protects impurities entering the fuel tank (26) during refuelling.
Remove the fuel tank cap (27) by turning in an anti-clockwise direction
(Fig AB).
3. Remove the fuel tank inlet lter (24) (Fig AC) and wash thoroughly in petrol.
4. Re-assemble by putting the fuel tank inlet lter (24) back, and then
securing the fuel tank cap (27) in a clockwise direction until rmly
secured.
Never store generator with fuel in the tank indoors or in enclosed, poorly
ventilated areas, where fumes can reach an open ame, spark or pilot
light as on a furnace, water heater, clothes dryer or other gas appliances.
Ensure the fuel tank and carburettor are BOTH fully drained of fuel. With
the fuel tap in the open position, then open the fuel drain (10) on the
carburettor to drain the fuel totally from the fuel tank (26).
Check the fuel tap / lever (23) is turned o after draining the tank and
carburettor.
Drain and replace the engine oil.
Clean the generator with a damp soft cloth with mild detergent.
Do not clean the generator with water.
Check all nuts bolts and fasteners. Ensure they are tightened if needed
before storage.