51
• Digital In. Used to switch the audio input of all connected
ADAT transports to the fiber optic digital input.
• Track Delay. Used to turn track delays on or off, if delays have
been read from the ADAT tape header. Track delays can not be
entered from the AI-2 front panel.
6.5B Commands Menu
The commands menu is used to set default command operation
and to issue system commands. The read and write data com-
mands are selected in this menu. To perform a data read or save
operation, select a command, press the SETUP key to exit setup
mode and then press the STORE key to confirm the command.
Menu Submenu Option Description
COMMANDS Data Save SysEx ADAT data read and save selection.
Read SysEx See special operating mode #1.
Save Tape
Read Tape
Clr Header
Abort Default.
Read Tape: Auto Always prompt to read ADAT tape
header when new tape detected
(default).
Off
Read SysEx: Auto Allow MIDI SysEx to automatically
overwrite AI-2 header information.
Off Default.
• Data. Used to select a data read or save operation. The menu
defaults to Abort, this is used to terminate a data transfer
operation in progress. The special case, clear header, erases
the tape header information in the AI-2 so that information read
from a previous tape will not be inadvertantly stored to a new
tape.
• Read Tape. If set to AUTO will always prompt the user to read
data from the tape when the ADAT transports are loaded.
• Read SysEx. If set to AUTO MIDI SysEx information received
at the MIDI IN port will automatically overwrite the data header.