STOVE USED FOR LOCAL HEATING
ALFA TERM -27
INSTALLATION, SETUP AND OPERATION INSTRUCTIONS

Questions and Answers

  • T
    Teresa BurtonSep 23, 2025
    What to do if the grate is stuck during shaking in my Alfa Plam ALFA TERM 27?
    • R
      ricky87Sep 23, 2025
      If the grate is stuck during shaking in your Alfa Plam Stove, it's likely that a nail, debris, or other material is stuck on the grate. Clean the grate to remove any unwanted objects.
  • J
    James Johns Jr.Aug 23, 2025
    What to do if there is a sudden water temperature rise in my Alfa Plam ALFA TERM 27 system?
    • H
      hamiltonlisaAug 23, 2025
      If you notice a sudden rise in water temperature in your Alfa Plam Stove system, it could be due to several factors. First, air might be trapped in the system, so bleed the radiators. Check that all valves toward the radiators are open to ensure normal water circulation. A failing circulation pump can also cause this issue, so repair or replace it if necessary. In case of a power outage, open all valves that reduced the heating system, especially the by-pass valve, reduce the fire, and carefully monitor the system to ensure the water temperature does not exceed 90°C when the power returns.
  • R
    Robert GatesAug 25, 2025
    How to fix an Alfa Plam ALFA TERM 27 when the fire is not burning properly?
    • M
      Mary MurilloAug 26, 2025
      If the fire in your Alfa Plam Stove isn't burning properly, it could be due to a low chimney draft. Consider building a new chimney or repairing the old one. Also, check if the connecting flue pipes, stove, and chimney door are properly sealed to prevent "false air" from being drawn in.
  • M
    Mr. Paul LeeAug 27, 2025
    Why is there a sudden water pressure rise in my Alfa Plam Stove system?
    • E
      elliotttimothyAug 27, 2025
      A sudden water pressure rise in your Alfa Plam Stove system, caused by a water temperature increase, could be due to a reduced or completely empty expansion vessel. Try bleeding some air through the vessel's valve. If water leaks out, the membrane is damaged and the vessel needs replacement. If only air comes out, remove the vessel and apply additional pumping, ensuring the vessel pressure is equal to or higher than the height difference between the system's highest and lowest points. Air in the system can also cause this, so release the air.
  • T
    tanya36Aug 27, 2025
    Why is my Alfa Plam ALFA TERM 27 Stove smoking when used for the first time?
    • D
      Donald WatersAug 27, 2025
      It is normal for the Alfa Plam Stove to smoke a little during its first use due to slight burning and heating of the chimney and stove. This should stop after a while.
  • J
    Jennifer FletcherSep 18, 2025
    Why doesn't the thermometer or pressure gauge display anything on my Alfa Plam Stove?
    • B
      brittanynorrisSep 18, 2025
      If the thermometer or pressure gauge on your Alfa Plam Stove isn't displaying the system temperature or pressure, the thermometer or pressure gauge is likely faulty and needs to be replaced.
  • S
    Sandra McdonaldSep 15, 2025
    What to do if the safety valve isn't discharging water from my Alfa Plam ALFA TERM 27 Stove system?
    • B
      Benjamin MarksSep 15, 2025
      If the safety valve on your Alfa Plam Stove system is not discharging water and the pressure is below 3 (2.5) bar, the safety valve is likely faulty and needs to be replaced.
  • S
    Sara MartinezSep 16, 2025
    Why isn't the safety valve discharging water when the pressure is over 3 bar in my Alfa Plam ALFA TERM 27?
    • M
      Mark JordanSep 17, 2025
      If the pressure in your Alfa Plam Stove system is over 3 (2.5) bar and the safety valve isn't discharging water, the safety valve is faulty and needs to be replaced.
  • R
    Robin StevensSep 7, 2025
    How to fix Alfa Plam Stove radiators not heating along their entire length?
    • P
      Peggy MurphySep 7, 2025
      If your radiators are not heating along their entire length, it is likely due to air trapped inside. Bleed the air from the radiators using the release valve.
  • K
    kellerchristianSep 4, 2025
    Why won't the circulation pump activate on my Alfa Plam Stove?
    • B
      Brandon PowersSep 4, 2025
      If the circulation pump on your Alfa Plam Stove doesn't activate or trips the switch, check for power at the electrical connection and ensure all connectors are tight. If necessary, replace the switches or fix any motor or installation connection problems. A faulty capacitor could also be the cause, so replace it if needed. Additionally, a blocked rotor or deposits in the pump can prevent activation, so check if the rotor turns easily and dismantle/clean the pump if it's blocked.

Alfa Plam ALFA TERM 27 Specifications

General IconGeneral
EfficiencyWood: 77 %, Coal: 79 %
Weight167 kg
Height850 mm
Flue Diameter150 mm
FuelWood
Fuel TypeWood