Installation/Operation/Maintenance
Tumble Dryers
25 Pound (11.3 Kilogram) Capacity
30 Pound (13.6 Kilogram) Capacity
35 Pound (16 Kilogram) Capacity
Stacked 30 Pound (13.6 Kilogram) Capacity
Stacked 45 Pound (20.4 Kilogram) Capacity
55 Pound (25 Kilogram) Capacity
Starting Serial No. 0602004144
Refer to Page 6 for Model Identification
Original Instructions
Keep These Instructions for Future Reference.
(If this machine changes ownership, this manual must accompany machine.)
www.alliancelaundry.com
Part No. 70458301ENR7
January 2014

Table of Contents

Other manuals for Alliance Laundry Systems HT055N

Questions and Answers

  • S
    Steven GonzalesAug 12, 2025
    What to do if Alliance Laundry Systems HT055N Dryer has spark but no flame?
    • D
      Danielle PerkinsAug 12, 2025
      If your Alliance Laundry Systems Dryer has a spark but no flame, first ensure the gas is on. Also, check for 24 VAC at the gas valve. If the issue persists, there might be a problem with the control; in this case check the voltage between the gas valve terminal MV and GND on the control.
  • T
    Tricia ArnoldAug 16, 2025
    Why Alliance Laundry Systems HT055N valve is on but there is no spark during TFI?
    • M
      Mark TranAug 16, 2025
      If the valve is on but there's no spark during TFI in your Alliance Laundry Systems Dryer, it could be due to a shorted electrode. Another possible cause is an incorrect spark gap; ensure it's set to .094-.156 inch. Also, inspect the high voltage cable for faults or poor connections. Finally, control failure can cause this issue.
  • J
    Jennifer HallAug 23, 2025
    How to fix reset failure on Alliance Laundry Systems HT055N?
    • S
      stephensjessicaAug 23, 2025
      If you're experiencing a reset failure on your Alliance Laundry Systems Dryer, it might be because the reset switch was pressed too long; try resetting again. Another possibility is that the reset switch is shorted, in which case you should replace the switch.
  • E
    ewolfeAug 27, 2025
    What to do if Alliance Laundry Systems HT055N thermostat is on, but there is no spark or valve?
    • M
      Mike LozanoAug 27, 2025
      If the thermostat is on but there's no spark or valve activity in your Alliance Laundry Systems Dryer, first ensure the cable connects to the control and electrode, and that voltage is present at the gas valve. If the issue persists, the control might be bad; check the red LED for a steady on or flashing codes.
  • L
    Leslie BeckerAug 31, 2025
    How to reset Alliance Laundry Systems Dryer control in lockout mode?
    • M
      Marie WilsonAug 31, 2025
      If the control in your Alliance Laundry Systems Dryer is in lockout mode, a manual reset is needed. Reset it by pushing the red lockout button or use the front end control.
  • A
    Amy DiazSep 4, 2025
    Why does my Alliance Laundry Systems HT055N have nuisance shutdowns?
    • A
      Austin CastanedaSep 4, 2025
      Nuisance shutdowns in your Alliance Laundry Systems Dryer can be due to a poor or erratic ground. To resolve this, verify that there is a proper system ground. Ensure the igniter, flame sensor, and igniter module share a common ground with the burner.
  • C
    Chase FrenchSep 7, 2025
    What to do if the Alliance Laundry Systems Dryer control is in lockout mode?
    • J
      James RaySep 7, 2025
      If the control panel on your Alliance Laundry Systems Dryer is in lockout mode, you will need to manually reset it. You can do this by pushing the red lockout button or using the front end control.
  • J
    James WilliamsSep 10, 2025
    What to do if Alliance Laundry Systems Dryer flame is okay during TFI, but no flame sense after TFI?
    • J
      Julie ThompsonSep 12, 2025
      If the flame is okay during TFI but there's no flame sense after TFI in your Alliance Laundry Systems Dryer, check the electrode position and cleanliness. Also, inspect the high voltage wire. Poor grounding at the burner or a poor flame (check flame current) can also cause this issue.

Summary

Front Matter

Introduction

Model Identification

Lists all available model numbers for gas, steam, and electric dryers.

Contact Information

Safety Information

Important Safety Instructions

Crucial precautions for safe operation, installation, and maintenance of the appliance.

Specifications and Dimensions

Cabinet Dimensions (025-055 Series)

Provides detailed measurements for dryer models 025, 030, 035, and 055.

Cabinet Dimensions (T30;T45 Series)

Details the physical dimensions for T30 and T45 series tumble dryers.

Exhaust Outlet Locations (025-055 Series)

Exhaust Outlet Locations (T30;T45 Series)

Gas Connection Locations (025-055 Series)

Gas Connection Locations (T30;T45 Series)

Electrical Connection Locations (025-055 Series)

Electrical Connection Locations (T30;T45 Series)

Steam Connection Locations (025-035 Series)

Steam Connection Locations (T30 Series)

Installation

Pre-Installation Inspection

Guidelines for checking the dryer for shipping damage and verifying parts.

Location Requirements

Specifies suitable installation locations, considering floor and environmental conditions.

Position and Level the Tumble Dryer

Instructions on how to properly position and level the unit using the provided legs.

Fifth Leveling Leg

Details the installation and adjustment of the stabilizing fifth leveling leg.

Fire Suppression System

Information and requirements for the integrated fire suppression system.

Water Requirements

Specifies water pressure, flow rate, and temperature for the fire suppression system.

Water Connections

Procedures for connecting the water supply to the dryer's solenoid valve.

Electrical Requirements

Covers power supply, wiring, and circuit breaker recommendations.

Auxiliary Alarm

Explains the function and connection of the auxiliary alarm output signal.

To Reverse the Loading Door

Steps to change the dryer door from right-hinged to left-hinged.

Before Placing Tumble Dryer into Service

Final checks and preparations before the dryer is put into operation.

Required for CE Models Only

Specific items to complete for CE-certified models after installation.

Installing CE Gas Drying Tumble Dryer

General Information

Guidance for installing gas dryers in countries with different gas types or configurations.

CE Orifices

Table detailing gas orifices, pressures, and part numbers for CE models.

Properties of CE Gases

Table detailing properties of various gases used in CE regions.

Changing Gas Configuration

Procedures for converting the dryer for different gas types or pressures.

Specific Conversion Procedures

Detailed steps for specific gas conversion processes.

Exhaust Requirements

Layout, Make-Up Air, and Venting

Guidelines for dryer placement, airflow, and exhaust duct installation.

Individual Venting

Manifold Venting

Gas Requirements

Gas Supply Pipe Sizing and Looping

How to size and install gas supply piping for optimal pressure distribution.

High Altitude Burner Orifice Sizing

Guidance on selecting correct burner orifices for operation at higher altitudes.

Electrical Requirements

Wiring Diagram and Central Pay Wiring

Location of wiring diagrams and instructions for central pay system connections.

Grounding Instructions

Critical information on properly grounding the appliance for electrical safety.

Service;Ground Location

Identifies the locations of ground lugs and terminal blocks for service.

Connecting Electrical Service

Step-by-step guide for making the main electrical service connection.

Voltage Conversion Instructions

Procedures for converting the dryer for different voltage configurations.

Ferrite Ring Installation

Instructions for installing a ferrite ring to protect electronic controls.

Electrical Specifications

Tables detailing electrical requirements, breaker sizes, and wire gauges.

Steam Requirements

Piping Recommendations

Guidelines for steam supply and return line sizing and installation.

Steam Trap and Condensate Connections

Procedures for installing steam traps and connecting condensate return lines.

Single Drop Timer

Timer Modes and Operation

Explains various modes like Power-Up, Ready, Start, Run, Door Open, and End of Cycle.

Dipswitch Settings and Programming

How to configure drying times, cool down times, and other settings via dipswitches.

To Program a Short Test Cycle

Steps to run a basic test cycle to verify control functionality.

Error Codes

Operating Instructions

General Operation and Safety

Basic safety warnings and operational guidelines for using the appliance.

Emergency Stop Button On CE Models

How to use the emergency stop button on CE-approved models.

Control Panel Operations

Operating instructions for various control types like Digital Timer, OPL, Quantum, DX4.

Ignition System Operation

How the ignition control works and troubleshooting for CE and Non-CE models.

Adjustments

Gas Burner Air Shutter Adjustment

How to adjust the air shutter for optimal burner combustion and flame pattern.

Airflow and Door Adjustments

Adjusting the airflow switch, loading door switch, and door strike for proper function.

Maintenance

Daily Maintenance

Routine cleaning tasks to be performed daily for optimal performance.

Monthly Maintenance

Tasks to be performed monthly, including exhaust duct cleaning.

Periodic Maintenance

Tasks to be performed quarterly, bi-annually, and annually.

Fire Suppression System Maintenance Test

Procedure for testing the fire suppression system every three months.

Before You Call for Service

Removing Tumble Dryer from Service

Disposal of Unit

Alliance Laundry Systems HT055N Specifications

General IconGeneral
BrandAlliance Laundry Systems
ModelHT055N
CategoryDryer
LanguageEnglish

Related product manuals