Installation/Operation/Maintenance
Tumble Dryers
25 Pound (11.3 Kilogram) Capacity
30 Pound (13.6 Kilogram) Capacity
35 Pound (16 Kilogram) Capacity
Stacked 30 Pound (13.6 Kilogram) Capacity
Stacked 45 Pound (20.4 Kilogram) Capacity
55 Pound (25 Kilogram) Capacity
Starting Serial No. 0602004144
Refer to Page 6 for Model Identification
Original Instructions
Keep These Instructions for Future Reference.
(If this machine changes ownership, this manual must accompany machine.)
www.alliancelaundry.com
Part No. 70458301ENR7
January 2014

Table of Contents

Other manuals for Alliance Laundry Systems HTT45N

Questions and Answers

  • K
    Kim CooperAug 13, 2025
    What to do if Alliance Laundry Systems Dryer has spark but no flame?
    • C
      Christopher Stone Jr.Aug 13, 2025
      If your Alliance Laundry Systems Dryer has a spark but no flame, first ensure the gas is on. Also, check for 24 VAC at the gas valve. If the issue persists, there might be a problem with the control; in this case check the voltage between the gas valve terminal MV and GND on the control.
  • A
    Arthur WeberAug 16, 2025
    Why Alliance Laundry Systems HTT45N valve is on but there is no spark during TFI?
    • A
      amanda44Aug 16, 2025
      If the valve is on but there's no spark during TFI in your Alliance Laundry Systems Dryer, it could be due to a shorted electrode. Another possible cause is an incorrect spark gap; ensure it's set to .094-.156 inch. Also, inspect the high voltage cable for faults or poor connections. Finally, control failure can cause this issue.
  • L
    Lauren StrongAug 20, 2025
    What to do if Alliance Laundry Systems Dryer flame is okay during TFI, but no flame sense after TFI?
    • A
      Ashley FrankAug 20, 2025
      If the flame is okay during TFI but there's no flame sense after TFI in your Alliance Laundry Systems Dryer, check the electrode position and cleanliness. Also, inspect the high voltage wire. Poor grounding at the burner or a poor flame (check flame current) can also cause this issue.
  • A
    Austin WolfeAug 25, 2025
    How to fix reset failure on Alliance Laundry Systems Dryer?
    • T
      Terry RodriguezAug 25, 2025
      If you're experiencing a reset failure on your Alliance Laundry Systems Dryer, it might be because the reset switch was pressed too long; try resetting again. Another possibility is that the reset switch is shorted, in which case you should replace the switch.
  • P
    Pamela BrewerAug 28, 2025
    What to do if Alliance Laundry Systems HTT45N Dryer thermostat is on, but there is no spark or valve?
    • S
      stephenmccoyAug 28, 2025
      If the thermostat is on but there's no spark or valve activity in your Alliance Laundry Systems Dryer, first ensure the cable connects to the control and electrode, and that voltage is present at the gas valve. If the issue persists, the control might be bad; check the red LED for a steady on or flashing codes.
  • L
    Laura TaylorAug 31, 2025
    How to reset Alliance Laundry Systems Dryer control in lockout mode?
    • L
      larry13Aug 31, 2025
      If the control in your Alliance Laundry Systems Dryer is in lockout mode, a manual reset is needed. Reset it by pushing the red lockout button or use the front end control.
  • D
    David WhiteSep 4, 2025
    Why does my Alliance Laundry Systems Dryer have nuisance shutdowns?
    • E
      Erica GonzalezSep 4, 2025
      Nuisance shutdowns in your Alliance Laundry Systems Dryer can be due to a poor or erratic ground. To resolve this, verify that there is a proper system ground. Ensure the igniter, flame sensor, and igniter module share a common ground with the burner.
  • S
    Samantha WeberSep 8, 2025
    What to do if the Alliance Laundry Systems HTT45N Dryer control is in lockout mode?
    • R
      Robert MorrisSep 8, 2025
      If the control panel on your Alliance Laundry Systems Dryer is in lockout mode, you will need to manually reset it. You can do this by pushing the red lockout button or using the front end control.

Summary

Introduction

Model Identification

Lists all models covered by the manual, categorized by Gas, Steam, and Electric types.

Safety Information

Hazard Symbols and Statements

Explains DANGER, WARNING, CAUTION symbols and precautionary statements.

Important Safety Instructions

Provides crucial safety guidelines for operation and installation.

Specifications and Dimensions

Key Performance Specifications

Covers weight, dimensions, performance metrics, motor specs.

Cabinet Dimensions

Details cabinet dimensions for 025, 030, 035, 055 series.

Exhaust Outlet Locations

Specifies exhaust outlet diameters and positions for 025-055 series.

Installation

Pre-Installation Inspection

Procedures for checking crate, carton, and parts for shipping damage.

Location Requirements

Guidelines for selecting an appropriate installation site, avoiding water/weather.

Water Connections

Instructions for connecting the water supply for the fire suppression system.

Electrical Requirements

Details electrical power supply needs and connection procedures.

Gas Requirements

Gas Supply Pipe Sizing

Guidance on sizing gas supply pipes and installing loops for equal pressure.

High Altitude Burner Orifice Sizing

Instructions for adjusting burner orifice size for operation at high altitudes.

Electrical Requirements

Grounding Instructions

Essential guidelines for electrically grounding the tumble dryer for safety.

Connecting Electrical Service

Step-by-step procedure for connecting electrical service to the dryer.

Electrical Specifications

Technical details on voltage, amperage, breaker ratings, and wire sizes.

Steam Requirements

Steam Requirements Overview

Details steam pressure, pipe sizing, and connection considerations.

Piping Recommendations

Guidelines for steam supply and return line installation and trap placement.

Single Drop Timer

Setting Dry Time Dipswitches

Instructions for configuring drying time using dipswitches on the control.

Dipswitch Settings

Tables detailing dipswitch configurations for various heat times.

Operating Instructions

General Operation and Safety

Covers basic operation, safety warnings, cleaning, and loading.

Control Type Operations

Details operation for various controls like Dual Digital, OPL, DMP.

Diagnostic Microprocessor Control

Details the operation of the DMP control, including programs and features.

Adjustments

Gas Burner Air Shutter

Procedure for adjusting the air shutter for optimal burner performance.

Airflow Switch Adjustment

Information on the airflow switch and its function in ensuring proper drying.

Door Switch and Strike Adjustments

Instructions for adjusting the door switch and strike for proper operation.

Maintenance

Daily Maintenance Tasks

Routine daily tasks for cleaning and inspection of the tumble dryer.

Fire Suppression System Maintenance Test

Procedure for testing the fire suppression system every three months.

Before You Call for Service

Troubleshooting Guide

A guide to identify and correct common operational issues before calling service.

Removing Tumble Dryer from Service

Removal Procedure

Steps to safely disconnect and remove the tumble dryer from its installation.

Disposal of Unit

Environmental Disposal Information

Information on responsible disposal of the appliance according to WEEE directive.