Programming Supplement
1300546
10
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
How to Exit Programming Mode
To exit Programming Mode, press STOP keypad or
turn finisher off and on.
Temperature Regulation Hysteresis
(Variance)
This option allows the owner to define the hysteresis
(variance) for the temperature regulation.
How to Program Temperature Regulation
Hysteresis (Variance)
1. Control must be in Programming Mode. Refer to
Entering Programming Mode section.
2. The current value is shown in the Temperature
Display, while “H” is shown on the Speed
display.
Default value: 2 °C
Parameter range: 1- 5 °C (2 - 9 °F)
Precision: 1°C (1.8°F)
NOTE: With electrical heating by two resistor
groups, the hysteresis (variance) only affects the
second group, while the first is controlled in the
usual manner.
3. Press the Increase Preset Temperature keypad (+)
or Decrease Preset Temperature keypad (–) to
change the set value.
4. Press Display Preset Temperature keypad (SET)
to confirm the current value and proceed to the
next parameter.
How to Exit Programming Mode
To exit Programming Mode, press STOP keypad or
turn finisher off and on.
Temperature for Automatic
Shut-down
This option allows the owner to set the maximum shut-
down temperature of the machine.
How to Program Temperature for Automatic Shut-
down
1. Control must be in Programming Mode. Refer to
Entering Programming Mode section.
2. The current value is shown in the Temperature
Display, while “0” is shown on the Speed display.
Default value: 80 °C (176°F)
Parameter range: 1 - 180 °C (34 - 356 °F)
Precision: 1°C (1.8°F)
3. Press the Increase Preset Temperature keypad (+)
or Decrease Preset Temperature keypad (–) to
change the set value.
4. Press Display Preset Temperature keypad (SET)
to confirm the current value and proceed to the
next parameter.
How to Exit Programming Mode
To exit Programming Mode, press STOP keypad or
turn finisher off and on.
Heating Type
This option allows the owner to establish whether the
heating is electrical or by gas/steam.
How to Program Heating Type
1. Control must be in Programming Mode. Refer to
Entering Programming Mode section.
2. The current value is shown in the Temperature
Display, while “C” is shown on the Speed
display.
Default value: EL (Electrical)
Available values: EL (Electrical) or
GAS (Gas/Steam)
3. Press the Increase Preset Temperature keypad (+)
or Decrease Preset Temperature keypad (–) to
change the set value.
4. Press Display Preset Temperature keypad (SET)
to confirm the current value and proceed to the
next parameter.
How to Exit Programming Mode
To exit Programming Mode, press STOP keypad or
turn finisher off and on.