SWIMMING POOL
HEAT PUMP
INSTALLATION & OPERATION MANUAL

Questions and Answers

  • G
    ghallAug 16, 2025
    How to fix communication failure in ALLIANCE Heat Pump?
    • J
      Jonathan WrightAug 16, 2025
      If you're experiencing a communication failure with your ALLIANCE Heat Pump, it indicates a communication breakdown between the remote wire controller and the main board. To resolve this, check the wire connections between the remote wire controller and the main board.
  • L
    Lori Garcia DVMAug 19, 2025
    What to do if ALLIANCE ALLPH130R410 Heat Pump shows high pressure protect?
    • S
      Steven BarnettAug 19, 2025
      If your ALLIANCE Heat Pump is showing a high pressure protection error, it's likely because the exhaust pressure is too high, triggering the high pressure switch. You should check the high pressure switch and the cooling return circuit.
  • N
    Nicholas GrayAug 22, 2025
    What causes low pressure protect in ALLIANCE ALLPH130R410?
    • A
      Annette PriceAug 22, 2025
      If your ALLIANCE Heat Pump indicates low pressure protection, it means the suction pressure is low, activating the low pressure switch. To address this, check the low pressure switch and the cooling return circuit.
  • A
    autumnmccarthyAug 25, 2025
    Why is there a high temperature difference between water inlet and outlet in my ALLIANCE Heat Pump?
    • C
      Catherine GrayAug 26, 2025
      A high temperature difference between the water inlet and outlet in your ALLIANCE Heat Pump suggests that the water flow volume is insufficient or the water system pressure difference is small. You should check the flow volume and inspect the water system for blockages.
  • P
    Peter AlvarezAug 27, 2025
    How to troubleshoot flow switch failure in ALLIANCE Heat Pump?
    • J
      James MendezAug 27, 2025
      If your ALLIANCE Heat Pump is experiencing a flow switch failure, it indicates there is no water or very little water in the water system. Check the flow volume and verify if the water pump is failing.
  • P
    Patricia ColemanAug 30, 2025
    What to do if ALLIANCE ALLPH130R410 Heat Pump is antifreezing under cooling mode?
    • H
      Holly SmithAug 30, 2025
      If your ALLIANCE Heat Pump is antifreezing while in cooling mode, it suggests that the water flow volume is not enough. Check the flow volume and see if the water system is blocked.
  • P
    Philip HunterSep 2, 2025
    How to fix water inlet temp. sensor failure in ALLIANCE ALLPH130R410?
    • J
      Jacob CurtisSep 2, 2025
      If the water inlet temperature sensor is failing on your ALLIANCE Heat Pump, it could be due to an open or short circuit. To resolve this, check or change the water inlet temperature sensor.
  • G
    George NewmanSep 4, 2025
    What causes water outlet temp. sensor failure in ALLIANCE ALLPH130R410 Heat Pump?
    • W
      wrightjesusSep 4, 2025
      If the water outlet temperature sensor is failing on your ALLIANCE Heat Pump, it might be open or short circuit. You should check or change the water outlet temperature sensor.
  • W
    Willie KellySep 7, 2025
    How do I address an ambient temp. sensor failure in my ALLIANCE ALLPH130R410?
    • N
      Nathan FernandezSep 7, 2025
      If the ambient temperature sensor is failing in your ALLIANCE Heat Pump, it is likely due to an open or short circuit. In this case, check or replace the ambient temperature sensor.
  • D
    Dylan BakerSep 10, 2025
    What to do if pipe temp. sensor fails in ALLIANCE Heat Pump?
    • C
      Christina SchmidtSep 10, 2025
      If the pipe temperature sensor is failing on your ALLIANCE Heat Pump, it's likely because it's open or short circuit. You should check or change the pipe temperature sensor.

Summary

Specifications

Performance Data of Swimming Pool Heat Pump Unit

Detailed performance data for various heat pump models, including capacity, power, and noise.

Installation and Connection

Swimming Pool Heat Pumps Electrical Wiring

Covers the electrical wiring requirements and connection to the power supply for the heat pump.

Initial Startup of the Unit

Provides a step-by-step procedure for the initial startup of the heat pump after installation.

Usage and Operation

Function of Controller

Explains the functions of the controller's buttons and display areas for operating the unit.

Temperature Setting

Explains how to set the target temperature for heating or cooling modes using the controller.

Maintenance and Inspection

Trouble Shooting

Lists common malfunctions, their causes, and suggested solutions for troubleshooting.

Warranty