©2008 Allied Air Enterprises Inc., a Lennox International Inc. Company
Phone: (803) 738−4000
Service Literature
TCA
ROOFTOP UNITS
TCA−090−102−120−150 (10−08)
The TCA 7.5, 8.5 and 10 ton cooling package units are avail-
able in standard efficiency (090S, 102S, 120S) and high effi-
ciency (090H, 102H, 120H). The TCA 12.5 ton unit is avail-
able in standard efficiency only (150S). The TCA 090/150
series uses one cabinet size with cooling capacities of
93,000 to 140,000 Btuh (27.2 to 41 kW).
Optional electric heat is factory−or field−installed in TCA units.
Electric heat operates in single or multiple stages depending
on the kW input size. 7.5 kW to 45 kW heat sections are avail-
able for the TCA090 and 102 and 15 kW to 60 kW heat sec-
tions are available for the TCA120 and 150.
All units utilize two scroll compressors and are designed to
accept any of several different energy management thermo-
stat control systems with minimum field wiring. Factory or
field provided control options connect to the unit with jack
plugs. When "plugged in" the controls become an integral
part of the unit wiring.
Information contained in this manual is intended for use by
qualified service technicians only. All specifications are sub-
ject to change. Procedures outlined in this manual are pre-
sented as a recommendation only and do not supersede or
replace local or state codes.
If the unit must be lifted for service, rig unit by attaching four
cables to the holes located in the unit base rail (two holes at
each corner). Refer to the installation instructions for the prop-
er rigging technique.
WARNING
Improper installation, adjustment, alteration, service
or maintenance can cause property damage, person-
al injury or loss of life. Installation and service must
be performed by a licensed professional installer or
service agency.
WARNING
Refrigerant can be harmful if it is inhaled. Refrigerant
must be used and recovered responsibly.
Failure to follow this warning may result in person-
al injury or death.
ELECTROSTATIC DISCHARGE (ESD)
Precautions and Procedures
CAUTION
Electrostatic discharge can affect electronic
components. Take precautions during unit instal-
lation and service to protect the unit’s electronic
controls. Precautions will help to avoid control
exposure to electrostatic discharge by putting
the unit, the control and the technician at the
same electrostatic potential. Neutralize electro-
static charge by touching hand and all tools on an
unpainted unit surface before performing any
service procedure.
Table of Contents
Specifications 2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Options 4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Electrical Data 6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Blower Data 8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
I Unit Components 12. . . . . . . . . . . . . . . . . . . . . . . . . . . .
II Placement and Installation 24. . . . . . . . . . . . . . . . . . . .
III Start Up Operation 24. . . . . . . . . . . . . . . . . . . . . . . . . .
IV Charging 24. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
V Maintenance 26. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
VI Accessories 27. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
VII Wiring and Operating Sequence 33. . . . . . . . . . . . .

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the ALLIED COMMERCIAL TCA Series and is the answer not in the manual?

ALLIED COMMERCIAL TCA Series Specifications

General IconGeneral
BrandALLIED COMMERCIAL
ModelTCA Series
CategoryAir Conditioner
LanguageEnglish

Summary

Electrostatic Discharge (ESD) Precautions and Procedures

Precautions and Procedures

Steps to avoid electrostatic discharge damage to electronic controls.

Specifications

Cooling Performance

Cooling capacity, airflow, and efficiency ratings.

Standard Indoor Blower and Drive

Blower motor and drive specifications.

Electrical Data

7.5 & 8.5 Ton Standard / High Efficiency

Electrical specs for 7.5 and 8.5 ton models.

10 & 12.5 Ton Standard / High Efficiency

Electrical specs for 10 and 12.5 ton models.

Blower Data

TCA Parts Arrangement

TCA Control Box

Diagram and components of the TCA control box.

I-Unit Components

Control Box Components

Detailed breakdown of control box components and their functions.

B-Cooling Components

Compressors B1 and B2

Description of the unit's two scroll compressors.

Table 9 - Electric Heat Ratings

7.5 & 8.5 Ton Models

Electric heat kW ratings and electrical requirements.

Table 10 - Electric Heat Ratings

10 & 12.5 Ton Models

Electric heat kW ratings and electrical requirements.

II-Placement and Installation

Start Up - Operation

Procedures for initial unit startup and checks.

Charging

Guidelines for refrigerant charging and verification.

V-Maintenance

VII-Wiring Diagrams and Sequence of Operation

TCA090/150 UNIT DIAGRAM

Wiring diagram for the TCA090/150 unit.

Sequence of Operation - TCA090/150

1st Stage Cooling (compressor B1)

Sequence for first stage cooling activation.

Electric Heat Wiring Diagrams

Sequence of Operation - Electric Heat

FIRST STAGE HEAT

Sequence for first stage electric heating activation.

SECOND STAGE HEAT

Sequence for second stage electric heating activation.

Related product manuals