EasyManua.ls Logo

Allison Transmission 4500 RDS

Allison Transmission 4500 RDS
162 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5.0CAREANDMAINTENANCE
5.1PERIODICINSPECTIONS
NOTE:Thetermsuidandoilareusedinterchangeablyinthis
publication.Bothtermsrefertotheuidoroilinthetransmission
andnowhereelse.
CAUTION:Donotspraysteam,water,orcleaningsolutiondirectly
atelectricalconnectorsorthebreather.Fluidsforcedintoelectrical
connectorscancausefalsecodesandcross-talk.Steam,water,
orcleaningsolutionforcedintothebreatherwillcontaminatethe
transmissionuid.Sealallopenings,thebreather,andelectrical
connectionsbeforesprayingsteam,water,orcleaningsolutionon
thetransmission.
Itisveryimportanttocontinuallymonitortheuidlevelandconnections
fortheelectronicandhydrauliccircuits.Cleanandinspecttheexteriorof
thetransmissionatregularintervals.Severityofserviceandoperating
conditionsdeterminethefrequencyoftheseinspections.Makeregular
periodicinspectionsfor:
Propertransmissionuidll.Referto5.8PERIODICFLUIDLEVEL
CHECKS.
Transmissionuidthatisdiscolored,hasastrongodor,orexceededoil
analysislimits.
Presenceofenginecoolantinthetransmissionuid.
NOTE:Transmissionoverhaulisrequiredwhenthetransmission
hasbeencontaminatedwithenginecoolant.AllisonTransmission
recommendsallclutchfrictionplates,lockupclutch,solenoids,and
rusted/damagedpartsbereplacedduringtherebuild.
Presenceoftransmissionuidintheenginecoolingsystem.
Leakinguidaroundttingsorhydrauliclines.
79

Table of Contents

Related product manuals