EasyManua.ls Logo

AllPondSolutions FPP-3500 - Specifications

AllPondSolutions FPP-3500
13 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
My Unit is Cutting Out
1. For optimum function of the unit, we highly recommend the pump is
positioned on a brick, so it is not resting directly on the bottom on the pond.
This is to prevent large clumps of debris blocking the inlets and restricting the
flow.
2. Ensure that all O-rings are in place and well lubricated.
3. Locate the impeller and shaft in the pump and inspect for damage and clear
the fittings and parts of any waste build-up.
4. Ensure that the plastic propeller part of the impeller is attached to the
magnetic part and that they have not come apart or split. If these parts looks
fine and there are two rubber grommets fitted on each end of the shaft, or
already inside the fittings, then re-assemble the unit.
If none of the above resolves your issue, or you require spare parts for your
pump, please contact the supplier of your unit.
SPECIFICATIONS
FPP-3500
250
267 x 223 x 132
25mm FLEXIBLE HOSE
OUTLET FITS:
DIMENSIONS (WxHxL) (mm):
MAX HEIGHT (cm)
3500 L/H
MAX FLOW RATE:
MODEL:
FPP-4500
350
267 x 223 x 132
25mm FLEXIBLE HOSE
4500 L/H
FPP-5000
380
267 x 223 x 132
25mm FLEXIBLE HOSE
5000 L/H
42w
WATTAGE:
75w
100w
CABLE LENGTH:
10m (Plug not included)10m (Plug not included)10m (Plug not included)
220-240V
VOLTAGE:
220-240V 220-240V

Related product manuals