8
INSTALLATION
Recommendedinstallation
Productports
The productports are integratedinto thecenterhousing [4].Different port configurations canbe obtained
(withoutusingofascrewedpulsationdamperonly).ThestandardconfigurationoftheESeriesatdeliveryis
withthesuctioninlethorizontallyatthebottomandthedischargeoutlethorizontallyat
thetop(figure8.1).
Furtherpossibleconfigurations:
Suctioninletverticallyatthebottom,thedischargeoutlethorizontallyatthetop(figure8.2)
Toobtainthisconfiguration,theplugofthecenterhousing[13]hastoberemovedandsetinthe
standardinlet.
Suctioninlethorizontallyatthebottom,
thedischargeoutletverticallyatthetop(figure8.3)
Unscrewthehousingbolts[19],takeoffthesidehous ings[1]andturnthecenterhousing[4].
Remountthepumpandadjusttheplug[13]accordingly.

fig. 8.1 fig. 8.2
fig. 8.3