EasyManua.ls Logo

Amana Menumaster RC5PHBU2 - Component Testing Procedures; Relay Activation Tests for Magnetrons and Cavity Light

Amana Menumaster RC5PHBU2
36 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Component Testing Procedures
!
WARNING
To avoid risk of electrical shock, personal injury or death; disconnect power to oven and discharge capacitor
before servicing, unless testing requires power.
16022149
©2005 Maytag Services
18
Refer to Technical Sheets for specific model information.
NOTE: For the following test, place oven in Service Test Mode.
Relay Function Test Set-Up Meter
Setting
Probe Placement Results
K1 at
230 VAC
line voltage
Blower motor
Antenna motor
Cavity light
Disconnect
J2 connector
Ohms J1 pin 1 (Brown wire)
& J2 pin 4
Test mode 5 off no continuity
Test mode 5 on < 1
H.V. Board Relay Test
Three Magnetron Models
Relay Function Test Set-Up Meter
Setting
Probe Placement Results
K8
Magnetron 1
(Top rear) at
230 VAC
All wires
connected to
H.V. board
VAC E2 (Black wire)
& J4 pin 2 (Red wire)
Test mode 1 off – line voltage
Test mode 1 on – 0 volts
K4
Magnetron 2
(Top front) at
230 VAC
All wires
connected to
H.V. board
VAC E5 (Red wire)
& J3 pin 1 (Gray wire)
Test mode 2 off – line voltage
Test mode 2 on – 0 volts
K6
Magnetron 3
(Bottom) at
230 VAC
All wires
connected to
H.V. board
VAC J4 pin 4 (Black wire)
& J4 pin 6 (Black wire)
Test mode 3 off – line voltage
Test mode 3 on – 0 volts
Two Magnetron Models
Relay Function Test Set-Up Meter
Setting
Probe Placement Results
K8
Magnetron 1
(Top rear) at
230 VAC
All wires
connected to
H.V. board
VAC E5 (Red wire)
& J4 pin 2 (Red wire)
Test mode 1 off – line voltage
Test mode 1 on – 0 volts
K6
Magnetron 3
(Bottom) at
230 VAC
All wires
connected to
H.V. board
VAC J4 pin 4 (Black wire)
& J4 pin 6 (Black wire)
Test mode 3 off – line voltage
Test mode 3 on – 0 volts

Related product manuals