EasyManua.ls Logo

Amana RSKP0014 - Dual Motor DC Outdoor Motor Wiring

Amana RSKP0014
20 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
18
HIGH VOLTAGE!
DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS
UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO
DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.
WIRING DIAGRAMS

24VAC TRANSFORMER
12VA CLASS 2 ONLY
ON
OFF
MASTER SWITCH
IN1 COM
IN2
AUXILIARY
C
R
GL W 2
Y/W1 B
GH
REMOTE
THERMOSTAT
IAT
BLACK
ICT
RED
OCT
BLUE
IHD
ORANGE
OAT
GREEN
IDT
YELLOW
REV.
VALVE
ID
FAN
HIGH LOW
OD
FAN
HIGH
LOW
LINE 2
COMPRESSOR
HEATER 1 HEATER 2
LINE 1
DANGER HIGH VOLTAGE
DUAL MOTOR, DC OD MOTOR
RVC
COMP
S
C
R
YL
RD
BK
BK
TR
6
RD
GY
HTR
F
4
WH
GN
WHITE
WIRE
2
1
RD
BK
WH
WH
BK
3
HPS
* FOR A HEAT PUMP,
THERMOSTAT USED
ON A STRAIGHT
COOL UNIT
** GL - LOW SPEED
GH - HIGH SPEED
5
1
2
3
4
5
6
LOAD
COM
265
230
H
RCCF
C
WARNING: DISCONNECT POWER BEFORE SERVICING.
WIRING TO UNIT MUST BE PROPERLY POLARIZED
(FOR 265V) AND GROUNDED.
WHITE WIRE MUST BE CONNECTED AS SHOWN.
ON HEAT PUMP MODELS ONLY
BK ON LINE 2 WITH FUSE SHOWN CONNECTED FOR 265V
FOR 230 V &115 V, CONNECTED POWER CORD TO LINE 2
FOR REMOTE OPERATION, SEE CONFIGURATION CHART.
IF SUPPLY VOLTAGE IS 208V / 230V, USE THE 230V TAP
ON TRANSFORMER.
IF SUPPLY VOLTAGE IS 265V, USE THE 265V TAP
ON TRANSF
ORMER.
115V TRANSFORMER NOT SHOWN.
RD
COM
1650 1500 1350 1170
7 7
230 / 265
BK
GND
TO MOTOR
VSTM ID
RS485
OUTDOOR MOTOR SPEED SELECTION
MODEL STARTS WITH HIGH SPEED
VSTM BLACK
LOW SPEED
VSTM RED
PTH073G (00 TO 35)
1350 1170
DRY093G (00 TO 35)
1350 1170
DRY094G(00 TO 35)
1350 1170
PTC173G(00 TO 35)
1500 1350
CM OUTDOOR FAN MOTOR
COMP COMPRESSOR
EM EVAPORATOR MOTOR
FC FAN CAPACITOR
F FUSE
HPS HIGH PRESSURE SWITCH
HTR HEATER ELEMENT
RCCF RUN CAPACITOR
FOR COMPRESSOR, ANY FAN
RVC REVERSING VALVE
TR TRANSFORMER
VSM VARIABLE SPEED MOTOR
VSTM VATIABLE SPEED TERMINAL BOARD
USE COPPER
CONDUCTORS ONLY
CHASSIS
GN1
CONTROL PANEL
WIRE LEGEND
HIGH VOLTAGE
(FACTORY)
HIGH VOLTAGE
(FACTORY OR FIELD
LOW VOLTAGE
(FACTORY OR FIELD)
HIGH VOLTAGE
DC HARNESS
(FACTORY)
7
SEE TABLE FOR MOTOR SPEED SELECTION
GN
VT
EM
FAN
MOTOR
FC
BR
BR
VSM
CM
FAN
MOTOR
BK
RD
BK
RD
WH
REMOTE THERMOSTAT
OPERATION
COOLING UNIT
W / ELECTRIC HEAT
FUNCTION
CONNECT
R TO:
OFF
-----------
FAN
G **
COOL
G, Y / W1
HEAT
G, W2
OR
G, B, Y / W1*
HEAT PUMP W / AUXILIARY
ELECTRIC HEAT
FUNCTION
CONNECT
R TO:
OFF
-----------
FAN
G **
COOL
G, Y / W1
1ST STAGE
HEAT
G, B, Y / W1
2ND STAGE
HEAT
G, W2
8
BOARD SHOWS R AND C, PLEASE IGNORE.
NOTES:
8
8
UI CONNECTION
WIRE CODE
BR BROWN
BK BLACK
GN GREEN
GY GRAY
RD RED
VT VIOLET
WH WHITE
YL YELLOW

Related product manuals