Model and Manufacturing
numbers listed in this manual.
MODEL M/N
BBA24A2A P1206401C
BBA36A2A P1206402C
BBA48A2A P1206403C
BBA60A2A P1206404C
BBA24A2A P1206415C
BBA36A2A P1206416C
BBA48A2A P1206417C
BBA60A2A P1206418C
TECHNICAL INFORMATION MANUAL
BBA* Blowers
Refer to Service Manual RS6200003 for installation, op-
eration, and troubleshooting information.
All safety information must be followed as provided in
the Service Manual.
Refer to the appropriate Parts Catalog for part number
information.
®
is a trademark of Maytag Corporation and is used under license to Goodman
Company, L.P. All rights reserved.
Copyright © 2004 Goodman Company, L.P.
RT6221002 Rev. 1
December 2004
This manual is to be used by qualified HVAC technicians only. Goodman
does not assume any responsibility for property damage or personal injury
due to improper service procedures performed by an unqualified person.
Question and Answer IconNeed help?

Do you have a question about the Amana BBA24A2A and is the answer not in the manual?

Summary

BBA* Blowers Introduction and References

Manual Overview and Key Information Sources

Introduces the manual, lists model numbers, and directs users to service/parts documentation.

Product Identification and Safety

Model Number Decoding and Product Attributes

Explains how model numbers define product specifications and features for identification.

Critical Safety Warnings and Cautions

Highlights warnings for unqualified personnel and hazardous service conditions.

Product Design and Specifications

Blower Cabinet Design, Insulation, and Installation Flexibility

Details the two-piece design, insulation, and positioning options for installation.

Dimensional and Physical Specifications

Presents detailed dimensions, shipping weight, and blower motor specifications.

Electric Heater and Performance Data

Lists electrical data for heaters and airflow performance information.

Wiring Diagrams

BBA(24-60)A2 A Wiring Schematic

Illustrates the electrical connections for the BBA(24-60)A2A model.

BBA with EHK Electric Heater Wiring Diagrams

Shows electrical schematics for BBA units with various EHK electric heater configurations.

BBA with ECB Electric Heater Wiring Diagrams

Details electrical connections for BBA units with various ECB electric heater configurations.

Summary

BBA* Blowers Introduction and References

Manual Overview and Key Information Sources

Introduces the manual, lists model numbers, and directs users to service/parts documentation.

Product Identification and Safety

Model Number Decoding and Product Attributes

Explains how model numbers define product specifications and features for identification.

Critical Safety Warnings and Cautions

Highlights warnings for unqualified personnel and hazardous service conditions.

Product Design and Specifications

Blower Cabinet Design, Insulation, and Installation Flexibility

Details the two-piece design, insulation, and positioning options for installation.

Dimensional and Physical Specifications

Presents detailed dimensions, shipping weight, and blower motor specifications.

Electric Heater and Performance Data

Lists electrical data for heaters and airflow performance information.

Wiring Diagrams

BBA(24-60)A2 A Wiring Schematic

Illustrates the electrical connections for the BBA(24-60)A2A model.

BBA with EHK Electric Heater Wiring Diagrams

Shows electrical schematics for BBA units with various EHK electric heater configurations.

BBA with ECB Electric Heater Wiring Diagrams

Details electrical connections for BBA units with various ECB electric heater configurations.

Overview

This document serves as a technical information manual for BBA* Blowers, providing essential details for qualified HVAC technicians regarding their design, operation, and maintenance. The manual emphasizes the importance of adhering to safety guidelines and consulting relevant service and parts information.

Function Description

BBA blowers are designed as two-piece blower coil units, intended to be attached to cased evaporator coils such as CCA_FC_, CHA_TC_, or CHF_TC_ models. This modular design offers significant flexibility in system configuration, allowing for various mix-matching possibilities to suit different installation requirements. The primary function of these blowers is to circulate air through the HVAC system, working in conjunction with an evaporator coil to facilitate heating or cooling processes. They are capable of operating in multiple orientations, including upflow, counterflow, horizontal right, or horizontal left, which further enhances their adaptability to diverse installation environments. The blowers are constructed with R-4.2 insulation, contributing to energy efficiency by minimizing heat transfer.

Usage Features

The BBA blowers are designed for versatile application within HVAC systems. Their multi-positional capability allows them to be integrated into a wide range of residential or commercial setups, whether the airflow needs to be directed upwards, downwards, or horizontally. The product identification system, based on model and manufacturing numbers, is crucial for accurate identification of component parts, which is vital when requesting service or replacement parts. This system helps ensure that the correct components are used, maintaining the integrity and performance of the unit. The manual also provides detailed wiring diagrams for various configurations, including those with and without electric heaters, and for heat pump applications with approved thermostats. These diagrams are indispensable for proper electrical connection and system integration, ensuring the blower operates as intended within the broader HVAC system. The inclusion of LED flash codes for diagnostic purposes is a key usage feature, allowing technicians to quickly identify and troubleshoot issues related to normal operation, thermistor errors, system errors, and control board malfunctions. This diagnostic capability simplifies the troubleshooting process, reducing downtime and service costs. The blower performance data, presented in tables, provides airflow information across different static pressures and fan speeds (low, medium, high), enabling technicians to verify that the blower is delivering the required airflow for optimal system performance.

Maintenance Features

Maintenance of BBA blowers is primarily guided by the comprehensive information provided in this manual and the referenced Service Manual RS6200003. The manual strongly advises that only qualified HVAC technicians perform service procedures to prevent property damage, personal injury, or electrical shock. This emphasis on professional service underscores the complexity of the unit and the potential hazards involved. Key maintenance aspects include consulting the appropriate Parts Catalog for accurate part number information when replacements are needed, ensuring that the correct components are installed. The wiring diagrams are critical for electrical maintenance, allowing technicians to trace circuits, verify connections, and diagnose electrical faults. The LED flash code system is a direct maintenance aid, providing immediate diagnostic feedback that helps pinpoint the source of a problem without extensive manual testing. For instance, specific flash patterns indicate thermistor or control board errors, guiding the technician to the relevant area for inspection or repair. The manual also highlights the importance of proper insulation, noting that in areas of extreme humidity (consistently greater than 80%), the installer should insulate the exterior of the blower with insulation having a vapor barrier equivalent to ductwork insulation, provided local codes permit. This preventative measure helps mitigate moisture-related issues and maintain the unit's efficiency and longevity. Furthermore, the electrical heater data, including minimum circuit ampacity (MCA) and maximum overcurrent protection (MOP), is crucial for ensuring that the electrical system is correctly sized and protected, preventing electrical overloads and potential fire hazards. The manual explicitly warns against exceeding the listed overcurrent protection values to avoid the risk of fire. All safety information, as detailed in the Service Manual, must be followed during any maintenance or service operation, reinforcing a culture of safety and preventing accidents. The continuous availability of updated wiring diagrams is also a maintenance feature, as it ensures that technicians always have access to the most current electrical schematics, which is vital for accurate troubleshooting and repair.

Amana BBA24A2A Specifications

General IconGeneral
BrandAmana
ModelBBA24A2A
TypeControl Unit
Voltage Rating24V
CompatibilityAmana HVAC systems