22
EN
Resistance measurement
• Insert the black connector lead (S) into the
negative COM (black) terminal (I) and the red
connector lead(S) into the positive V (red)
terminal (M).
• Set the function switch (K) to the Ω/CAP
position.
• Connect the test probes (S) across the circuit
or component being measured.
• If OL appears on the display (F), the circuit or
device being tested is open or has a resistance
that is above the range of the product.
• The stabilized value on the display (F) is read as
the actual reading.
Capacitance measurement
• Insert the black connector lead (S) into the
negative COM (black) terminal (I) and the red
connector lead(S) into the positive V (red)
terminal (M).
• Set the function switch (K) to the Ω/CAP
position.
• Press the MODE/VFD button (H) to shift to
measuring the capacitance F (Farad).
• Connect the test probes (S) across the circuit
or the capacitor being measured.