EasyManua.ls Logo

Amcor AMB12KE410A - User Manual

Amcor AMB12KE410A
11 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
ENGLISH
INSTRUCTION MANUAL
AMB12
PORTABLE AIR CONDITIONER
AMB
12KE410A
Question and Answer IconNeed help?

Do you have a question about the Amcor AMB12KE410A and is the answer not in the manual?

Summary

AMCOR Portable Air Conditioner Manual

Product Identification

Identifies the Amcor AMB12KE410A portable air conditioner model.

General Safety Information

Safety Precautions and Usage

Emphasizes reading the manual, safe operation, and keeping it for reference.

Warning: Damaged Cord and Plug

Warns against using a damaged cord or plug and specifies qualified service for replacement.

Child Safety and Supervision

Appliance is not for unsupervised children or infirm persons; supervision is required.

Installation Clearance Requirements

Specifies minimum 50 cm clearance from structures and combustible surfaces.

Prohibited Item Placement

Advises against placing items, such as clothing, on top of the appliance.

Plug and Fuse Replacement

Earthing and Plug Type

States the appliance must be earthed and refers to the rating plate for voltage and power input.

Plug Replacement Procedure

Instructions for replacing the plug with an earthed one and discarding unsuitable plugs.

Fuse Rating and Standard

Specifies the replacement fuse rating as 13 Amps conforming to BS1362.

Product Parts and Components

Main Unit Components

Identifies the main components of the portable air conditioner, numbered 1 through 9.

Accessories and Fittings

Identifies accessories and fittings, numbered 10 through 18.

Hose Assembly Diagram

Illustrates the assembly of the exhaust hose with PVC tube and suction cups.

Electrical Wiring and Fuse

Wire Color Code for Plug

Details the wire color coding for connecting the plug terminals: Blue to N, Brown to L, Yellow/Green to E.

Operation and Safety Guidelines

Pre-Operation Setup

Advises leaving the unit upright for at least 2 hours before first use.

Company Introduction

Brief background on Amcor's specialization in indoor environment control products.

General Safety Instructions

Lists essential safety precautions for operating the air conditioner.

Electrical Connection Requirements

Specifies connection to a 220-240V earthed outlet and consulting an electrician if unsure.

Appliance Care and Maintenance

Provides guidelines on cleaning, maintenance, and service to avoid damage or voiding warranty.

Cord Safety Warning

Reiterates the warning against operating with a damaged cord or leading it over sharp edges.

Installation Procedures

Exhaust Hose Installation Overview

Explains the unit's portability and the ease of fitting the exhaust hose through a window or wall.

Foam Strip Window Fitting

Detailed steps for installing the exhaust hose using the foam strips and window fitting kit.

Round Window Connector Fitting

Instructions for installing the exhaust hose using the round window connector and cap.

Exhaust Hose Usage Guidelines

Important notes on hose length, avoiding kinks, and ensuring free airflow for proper operation.

Operating the Air Conditioner

Power ON;OFF Functionality

Explains how to turn the unit on and off using the power button.

Timer Setting and Pre-setting

Details how to set the operating timer (1-12 hours) and pre-set the unit's activation time.

Mode Selection

Describes how to select operating modes: AUTO, cooling, and ventilation.

AUTO Mode Operation

Explains how AUTO mode selects fan speed based on ambient temperature.

Fan Speed Adjustment

Instructions on selecting the desired fan speed: high or low.

Advanced Operation Features

Temperature Control Settings

Explains how to select the desired operating temperature between 18°C and 32°C.

Sleep Mode Functionality

Details the sleep mode function, including gradual temperature rise and automatic shut-off.

Remote Control Operation

Mentions that all functions are available via remote control and its battery requirements.

Air Flow Direction Adjustment

Describes how to adjust the air flow direction using vertical and horizontal louvres.

Important Operational Notices

Provides notices regarding unit start-up delay, switching off delay, and cooling resumption.

Water Drainage Procedures

Water Tank Full Indication

Explains that water is extracted during cooling and the unit stops when the tank is full, indicated by a blinking LED.

Drainage Using Water Tray

Step-by-step guide for draining condensed water using the supplied water tray.

Continuous Drainage via Water Tube

Instructions for continuous drainage using the supplied water tube and extending it.

Maintenance and Storage

Housing Cleaning Instructions

Guidelines for cleaning the unit's exterior using a damp cloth and avoiding harsh chemicals.

Filter Cleaning and Replacement

Instructions on how to clean the air filters, including washing the foam filter and drying.

Filter Operation Warning

Crucial notice stating the unit must never be operated without its filters.

End of Season Storage Guide

Recommendations for proper storage of the unit at the end of the season.

Power Cord Storage Method

Shows how to tidy away the power cord when the unit is not in use.

Troubleshooting Guide

Unit Not Functioning Solutions

Troubleshooting steps for when the unit does not function, covering power and water tank status.

Poor Performance Troubleshooting

Solutions for poor performance, including environmental factors, filter status, and settings.

Addressing Unit Noise

Advice for a noisy unit, suggesting placement on an even surface.

Compressor Not Working Issues

Guidance for when the compressor is not working, likely due to overheat protection.

Warning: Avoid Self-Repair

Strong warning against attempting any self-repair to avoid warranty loss and safety risks.

Technical Specifications

Model and Cooling Capacity Details

Lists the model number and its cooling capacity in BTU/h and kW.

Power Consumption and Current

Details the mains voltage, power consumption in Watts, and current in Amps.

Performance Metrics

Provides data on dehumidification rate, air delivery volume, and recommended room size.

Refrigerant and Compressor Information

Information regarding the refrigerant used and compressor details.

General Unit Specifications

Lists specifications for fan speeds, thermostat, timer, physical dimensions, and weight.

Specification Updates and Label Reference

Notes that specifications are subject to change and to refer to the rating label for precision.

Product Disposal Guidance

Reminder about proper disposal of waste electrical products at local recycling centers.