TECHNICAL DATA
Model D850E D950E
Mains 230 V / 50 Hz
Power consumption W 850 1200
Current (
operation) A 4.5 6
Current (
at start) A 18 24
Water extraction
at 32 °C, 90 % RH L/24h 45 60
Refrigerating agent R407C
Airflow (
at high fan speed) m3/h 500 680
Operating temperature °C 7 – 35
Dimensions
w x h x d mm 660 x 750 x 345
Weight (
net)kg3944
Meets EEC directive 73/23/CE (LVD). Specifications may change without prior notice.
TROUBLE SHOOTING
If the dehumidifier does not operate:
Make sure the unit is plugged in.
Ensure the humidistat control is turned on.
If the unit is noisy:
Make sure the dehumidifier is standing solidly and level.
If the unit is leaking:
Check the drainage tube for correct fitting.
Check for twists and bends in the drainage tube.
Check the drainage tube for a sufficient slope.
Check and make sure that the outlet of the drainage pipe is not under the water-
level in the drain.