EasyManua.ls Logo

American Dryer Corp. Phase 7 / OPL ensor Activated Fire Extinguishing System D120 User Manual

American Dryer Corp. Phase 7 / OPL ensor Activated Fire Extinguishing System D120
56 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
D120 Installation Manual
Phase 7 / OPL
Sensor Activated Fire Extinguishing System
WARNING: For your safety the information in
this manual must be followed to minimize the
risk of fire or explosion or to prevent property
damage, personal injury or death.
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch; do not
use any phone in your building.
Clear the room, building or area of all
occupants.
Immediately call your gas supplier from a
neighbors phone. Follow the gas suppliers
instructions.
If you cannot reach your gas supplier, call
the fire department.
Installation and service must be performed by a
qualified installer, service agency or the gas
supplier.
AVERTISSEMENT: Assurez-vous de bien
suivre les instructions données dans cette notice
pour réduire au minimum le risque d’incendie
ou d’explosion ou pour éviter tout dommage
matériel, toute blessure ou la mort.
Ne pas entreposer ni utiliser d’essence ni
d’autres vapeurs ou liquides inflammables à
proximité de cet appareil ou de tout autre
appareil.
QUE FAIRE SI VOUS SENTEZ UNE ODEUR
DE GAZ:
Ne pas tenter d’allumer d’appareils.
Ne touchez à aucun interrupteur. Ne pas
vous servir des téléphones se trouvant dans
le bâtiment.
Évacuez la pièce, le bâtiment ou la zone.
Appelez immédiatement votre fournisseur
de gaz depuis un voisin. Suivez les
instructions du fournisseur.
Si vous ne pouvez rejoindre le fournisseur
de gaz, appelez le service des incendies.
L’installation et l’entretien doivent être assurés par
un installateur ou un service d’entretien qualifié
ou par le fournisseur de gaz.
ADC Part No. 113179-3
American Dryer Corporation
88 Currant Road
Fall River MA 02720-4781 USA
Telephone: +1 (508) 678-9000 / Fax: +1 (508) 678-9447
e-mail: techsupport@amdry.com
www.amdry.com
Question and Answer IconNeed help?

Do you have a question about the American Dryer Corp. Phase 7 / OPL ensor Activated Fire Extinguishing System D120 and is the answer not in the manual?

American Dryer Corp. Phase 7 / OPL ensor Activated Fire Extinguishing System D120 Specifications

General IconGeneral
BrandAmerican Dryer Corp.
ModelPhase 7 / OPL ensor Activated Fire Extinguishing System D120
CategoryDryer
LanguageEnglish

Summary

SECTION I IMPORTANT INFORMATION

Receiving and Handling

Procedures for inspecting and accepting dryer shipments.

Safety Precautions

Critical safety guidelines for operation and installation.

SECTION II SPECIFICATIONS/COMPONENT IDENTIFICATION

Specifications

Technical details and measurements of the dryer.

Component Identification

Identifies key parts of the dryer with diagrams.

SECTION III INSTALLATION PROCEDURES

Location Requirements

Guidelines for selecting a suitable installation site.

Unpacking/Setting Up

Steps for removing the dryer from packaging and initial setup.

Dryer Enclosure Requirements

Specifies clearances and enclosure needs for the dryer.

Fresh Air Supply Requirements

Details on necessary ventilation and make-up air.

Exhaust Requirements

Guidelines for proper dryer exhaust system installation.

Electrical Information

Requirements and procedures for electrical connections.

Gas Information

Instructions for gas supply connections and safety.

Steam Information

Guidelines for steam supply, pressure, and connections.

Preparation For Operation/Start-Up

Pre-operation checks and procedures before initial use.

Preoperational Tests

Tests to perform before the dryer is put into service.

Compressed Air Requirements

Specifications for compressed air supply.

Shutdown Instructions

Procedures for taking the dryer out of service.

SECTION IV SERVICE/PARTS INFORMATION

Service

Information on who should perform service and how to contact support.

Parts

Details on how to order replacement parts.

SECTION V WARRANTY INFORMATION

Returning Warranty Cards

Instructions for completing and returning warranty cards.

Warranty

Information on obtaining warranty details.

Returning Warranty Parts

Procedures for returning parts for warranty claims.

SECTION VI ROUTINE MAINTENANCE

Cleaning

Instructions and schedules for cleaning lint and components.

Adjustments

Procedures for adjusting components after installation and periodically.

Lubrication

Lubrication intervals and types for dryer bearings.

SECTION VII MANUAL RESET BURNER HI-LIMIT INSTRUCTIONS

Phase 7

Instructions for resetting the burner hi-limit for Phase 7 models.

Dual Timer

Instructions for resetting the burner hi-limit for Dual Timer models.

SECTION VIII DATA LABEL INFORMATION

Data Label

Explanation of the information found on the dryer's data label.

SECTION IX PROCEDURE FOR FUNCTIONAL CHECK OF REPLACEMENT COMPONENTS

For Heat Control Module Ignition Circuit

Procedure for checking the ignition circuit of the heat control module.

SECTION X PHASE 7 OPL SYSTEM DIAGNOSTICS

DIAGNOSTIC (L.E.D. DISPLAY) FAULT MESSAGES

Explains fault messages displayed via LEDs on the control board.

SECTION XI OPTIONAL SENSOR ACTIVATED FIRE EXTINGUISHING (S.A.F.E.) SYSTEM

Theory of Operation

Explains how the S.A.F.E. system detects and extinguishes fires.

OPL S.A.F.E. SYSTEM CHECK PROCEDURE

Procedure to test the functionality of the S.A.F.E. system's water valve.

Related product manuals