REV. 1/9/2010 Page 1 of 9
AF-1000 Series
Manual Gas Control Valve
APPLICATION
The AF-1000 Manual Gas Control Valve is designed for use in gas in hearth products, wall mount furnaces, and space heating
appliances. For use with Propane or natural gas.
AF-1XXX MODEL IDENTIFICATION
A F 1 X X X
0 = With Safety Seal
1 = With Safety Seal (3-Plunger)
5 = With-out Safety Seal
American Flame
0 = Manual without Solenoid.
1 = With ON/OFF Solenoid (Remote)
1000 Series 2 = With ON/OFF/Variable DC Motor Drive (Remote)
3 = With High/Low Step Motor (Model AF-1000MOT)
4 = Manual for 3-Plunger Safety Seal
Type of Valve
0 = Vented Control Valve
1 = Ventfree Control Valve
FEATURES
Multi positional (All Plans) / Versatile Mounting.
Power unit powered by 30mv thermocouple.
CSA rated capacity 80,000 BTU/hr at 1” wc pressure drop (All inlet/outlet configurations).
AF-1000 series available with 0ºF to 225ºF (-18
0
C to 107ºC) temperature range.
Multiple outlet connections single inlet connection (All 3/8” NPT).
Fine mesh screens on inlet.
Multiple mounting holes (All 10-24 SAE threads)
Low profile / Compact size.
Easy pilot adjustment screw (Located on the front of the valve) (Vented Only).
No conversation from natural to propane gas required.
White lettering on OFF/ON/PILOT knob.
Vented / Vent free models available.
1” and 2” plastic extension knobs available.
A
F
A M E R I C A N F L A M E
f i r e - p a r t s . c o m
Question and Answer IconNeed help?

Do you have a question about the american flame AF-1000 Series and is the answer not in the manual?

Summary

Specifications

Installation

Location Guidelines

Provides instructions for selecting an appropriate installation location.

Piping to Gas Control

Details requirements for connecting gas piping to the control valve.

Install Control

Pilot Gas and Lighting Procedure

DC Powered Feature of the AF1000

Gas Leak Test

Procedure for checking for gas leaks after installation or maintenance.

Check Safety Shutdown Performance

Maintenance

Troubleshooting

Pilot Not Staying Lit

Diagnoses issues when the pilot burner fails to remain lit.

Main Burner Not Coming ON

Troubleshoots why the main burner does not ignite.

american flame AF-1000 Series Specifications

General IconGeneral
Brandamerican flame
ModelAF-1000 Series
CategoryControl Unit
LanguageEnglish

Related product manuals