American Standard 4A7V7X36A1000A User Manual

American Standard 4A7V7X36A1000A
32 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
SSAAFFEETTYY WWAARRNNIINNGG
Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating, and air-conditioning
equipment can be hazardous and requires specific knowledge and training. Improperly installed, adjusted or altered equipment by an unqualified person
could result in death or serious injury. When working on the equipment, observe all precautions in the literature and on the tags, stickers, and labels that
are attached to the equipment.
April 2023
1111--BBCC4477DD11--11AA--EENN
American Standard Link Variable Speed Heat Pumps and Air
Conditioners
4A6V7X24A1000A
4A6V7X36A1000A
4A6V7X48A1000A
4A6V7X60A1000A
4A7V7X24A1000A
4A7V7X36A1000A
4A7V7X48A1000A
4A7V7X60A1000A
TM
The Diagnostics Mobile App is available by scanning a QR
code located inside this unit or by searching for the Trane or
American Standard Diagnostics App in your App Store
®
.
This system must include a A/T HUI2360A200U thermostat
and a TSYS2C60A2VVU system controller to operate and is
Link communicating only.
NNoottee:: “Graphics in this document are for representation
only. Actual model may differ in appearance.”
Installer’s Guide
Question and Answer IconNeed help?

Do you have a question about the American Standard 4A7V7X36A1000A and is the answer not in the manual?

American Standard 4A7V7X36A1000A Specifications

General IconGeneral
BrandAmerican Standard
Model Number4A7V7X36A1000A
TypeAir Conditioner
SEERUp to 17
RefrigerantR-410A
Phase1
Frequency60 Hz
Cooling Capacity3 Tons
Nominal Cooling Capacity (BTU)36000 BTU
Cooling Capacity (MBH)36 MBH
SEER (Up to)17 SEER
Voltage208/230V

Summary

Installer's Guide

Safety Section

Refrigerant Line Considerations

Refrigerant Line Brazing

Refrigerant Line Leak Check

Refrigerant Line and Indoor Coil Evacuation

Service Valves

Electrical – Low Voltage Communicating

Electrical – High Voltage

Start Up

System Charge Adjustment

Subcool Charging Correction Charts

Refrigerant Charging Chart

Provides R-410A subcooling values based on liquid temperature and design subcooling.

Charging the Unit

Defrost Control (Heat Pump only)

Demand Defrost

Measures heat pump performance using ambient and coil temps for defrost initiation.

Checkout Procedures