BID Detect –
Charger is attempting to detect if the connected battery
contains a BID/WBID
BID Init –
Charger has established communication with the BID/WBID
and is reading ALL of the available data.
BID Refresh –
Charger is reading the latest Battery Temperature,
Battery VPC, and Accumulated Charge/Discharge data from the bat-
tery.
Mod X Over Temp –
Module #X is reporting that it is overheating.
In this scenario, the system will attempt to cool down the module by
reducing power.
Mod X IGBT Err –
Module #X is reporting a problem with
its IGBT drive
Mod X Short –
Module #X is reporting a Short Circuit condition
on its output.
Mod X Phase Loss –
Module #X is reporting a Phase Loss
Mod X Over Curr –
Module #X is reporting an overcurrent issue
Mod X Offline –
Module #X is offline and not providing power.
Hot Disconnect –
Charge cycle aborted due to disconnecting the
battery while charging.
Manual Stop –
User requested to stop the charge cycle by pressing
the red button on the front door.
Cell Validate –
The charger is determining the correct cell count for
the battery when in Multi-Cell mode.
Writing BID –
The charger is writing information to the BID.
Mod X Temp Err –
Module #X has overheated and is shutdown.
well as any warnings or engine faults.
CHARGE STATUS
Statistics will have a real-time status. Archive records will have
the termination code.
Session Start –
Charge Session started
Start Current –
Charger is providing Start Current
Gassing –
Charger is regulating voltage to the Battery
80 Percent –
Charge session has passed the 80% complete point.
Finish Current –
Charger is providing finishing current.
Lid –
Charger is modulating LID voltage (maximum charge voltage).
Charge Complete –
Charge Session Complete
High Battery –
High Battery Volts Reject Error.
Batt Over Temp –
Battery Overtemperature Error
Low Volt Shut –
Low Voltage Shutdown Error
Charge Curve Err –
Charge Curve Error
Low Curr Shut –
Low Current Shutdown
High Curr Shut –
High Current Shutdown
Backup Timer –
Session timeout due to backup timer.
Over Max AH –
Over Max AH returned.
Over Temp Err –
Charger overtemp error
DIDT Shutdown –
DiDt Shutdown error
Engine Error –
Charge Engine Error
Over Temp Warn –
Charger Cabinet is overheating, (charging power
may be reduced in this state)
Output Limited –
The charger is unable to meet the required output
Low Batt Reject –
Low Battery Volts Reject Warning
SM Inhibit –
Charging temporarily halted due to Start Mode
Batt Cycle Delay –
Multi-Cell charging delay active. This delay oc-
curs to avoid issues with the user disconnecting and reconnecting a
battery quickly when the charger is set for Multi-Cell Mode
No Gas Inhibit –
Charging is delayed due to No Gassing being active
Equalize –
Charger is currently equalizing
Refresh Started –
Charger is in a 60 second countdown to begin a
refresh.
Battery Watering –
Charger is running the battery watering routine.
Addition Charge –
Charger is running additional Finish Current
charge as specified by the customer.
BID Comm Failed –
Communication with the BID device has ended
and failed.