46-635 External Cage Displacer Actuated Liquid Level Switches
19
4.3 Specifications
4
.3.4 Dimensions – Flanged Top Cage Design
inches (mm)
Model
Code
Connection
Size
NPT or SW Flanges
A
B
C
D
A
B
C
D
Std. 14" Std. 14" Std. 14" Std. 14"
C74
300#
1"
n/a n/a n/a n/a n/a n/a
18.97
(482)
n/a
5.45
(138)
26.00
(660)
n/a n/a1–1
1
⁄2"
6.19
(157)
2"
6.25
(159)
C74
600#
1"
n/a n/a n/a n/a n/a n/a
18.97
(482)
n/a
5.45
(138)
26.38
(670)
n/a n/a1–1
1
⁄2"
6.19
(157)
2"
6.25
(159)
H15
1"
11.50
(292)
14.00
(356)
3.62
(92)
23.12
(587)
25.63
(651)
3.35
(85)
11.50
(292)
14.00
(356)
9.50
(241)
23.12
(587)
25.63
(651)
3.35
(85)
1–1
1
⁄2"
3.69
(94)
2"
3.81
(97)
H32
1"
11.50
(292)
14.00
(356)
4.40
(112)
24.25
(616)
26.76
(680)
2.75
(70)
11.50
(292)
14.00
(356)
10.00
(254)
24.25
(616)
26.76
(680)
2.75
(70)
1–1
1
⁄2"
4.53
(115)
2"
4.91
(125)
H52
1"
11.64
(296)
14.00
(356)
4.50
(114)
25.33
(643)
27.71
(704)
3.96
(101)
11.64
(296)
14.00
(356)
10.00
(254)
25.33
(643)
27.71
(704)
3.96
(101)
1–1
1
⁄2"
4.63
(115)
2"
5.00
(127)
Model
Code
Connection
Size
NPT or SW Flanges
A B C A B C
C
74
300#
1" 15.65 (398) 2.77 (70) 22.69 (576)
18.33 (466)
5.45 (138)
25.38 (645)1–1
1
⁄2" 15.77 (401) 3.19 (81) 22.81 (579) 6.19 (157)
2" 15.90 (404) 3.31 (84) 22.94 (583) 6.25 (159)
C74
600#
1" 15.65 (398) 2.77 (70) 23.06 (586)
18.33 (466)
5.45 (138)
26.38 (670)1–1
1
⁄2" 15.77 (401) 3.19 (81) 23.19 (589) 6.19 (157)
2" 15.90 (404) 3.31 (84) 23.31 (592) 6.25 (159)
H15
1"
14.85 (377)
3.62 (89)
23.12 (587) 18.33 (466) 9.50 (241) 26.63 (676)1–1
1
⁄2" 3.69 (91)
2" 3.81 (97)
H32
1"
14.25 (362)
4.40 (112)
24.25 (616) 17.50 (444) 10.00 (254) 27.51 (699)1–1
1
⁄2" 4.53 (115)
2" 4.91 (125)
H52
1"
15.60 (396)
4.50 (114)
25.33 (643) 19.21 (488) 10.00 (254) 28.96 (736)1–1
1
⁄2" 4.63 (118)
2" 5.00 (127)
Dimensions–Side/Side
Dimensions–Upper Side/Bottom