Sequoia / Tahoe Series User Manual California Instruments
M447352-01 REV-A 97
Figure 4-22: Output Voltage Monitor Pinout Diagram for Phase C
4.3.5 Output Current Monitor (IMON)
Current Monitor provides functionality to monitor the scaled-down output current of the unit; refer to Figure
4-13 and Table 4-2 for pin-out details. The scaled-down Output current of each phase could be monitored
between the IMON terminals of the external analog control signal connector (Pin-6: IMON for Phase A,
Pin-7: IMON for Phase B, and Pin-8: IMON for Phase C) and Pin-9 (Return / ISO_COM). Measurement of
output current 0 to 100% of full-scale rated output corresponds to 0 to ±10V pk. Refer to Figure 4-23,
Figure 4-24, and Figure 4-25.
Figure 4-23: Output Current Monitor Pinout Diagram for Phase A
Figure 4-24: Output Current Monitor Pinout Diagram for Phase B