Sequoia / Tahoe Series User Manual California Instruments
206 M447352-01 REV-A
PONS WAVEFORM PONS menu: Selects the type of output waveform, either the
standard sine, square, or clipped-sine, or one that is
user-defined; the default is a sine wave. The clipped-sine
waveform has an additional programmable parameter,
CLIP % THD.
Figure 5-191. PONS Waveform Settings
PONS ALC PONS menu: Selects how the output voltage will be regulated;
default is ALC on:
ON: The RMS digital regulator is enabled, and shutdown will be
executed if a loss of regulation occurs.
OFF: Regulation of the output voltage does not utilize the RMS
digital regulator, and shutdown that is dependent on regulation
would not occur.
Regulate: The RMS digital regulator is enabled, but shutdown
will not be executed if loss of regulation occurs.
Figure 5-192. PONS ALC Settings
PONS PHASE NUMBER PONS menu: Selects the output configuration, either 1-Phase or
3 Phase, for 3-Phase models; the default is 3-Phase.