Sequoia / Tahoe Series User Manual        California Instruments 
 
16  M447352-01 REV-A 
SQ0450  81 323  40  161 
SQ0540  68 269  33  134 
Table 2-3: Resistance range for different models- Three Phase DC mode 
 
Model  Inductance Range (per phase) – AC mode 
Minimum Inductance (uH)  Maximum Inductance (mH) 
166 V  333 V  166 V  333 V 
SQ0022  294 1179 1468 5891 
SQ0030  221 884  1098  4417 
SQ0045  147 590 732 2945 
SQ0090  74 295 366 1468 
SQ0135  50 197 242 980 
SQ0180  37 148 181 732 
SQ0270  25 99  121  487 
SQ0360  19 74 89 366 
SQ0450  15 59 73 292 
SQ0540  13 50 60 242 
Table 2-4: Inductance range for different models- Three Phase Mode 
 
Model  Capacitance Range (per phase)- AC mode 
Minimum Capacitance (uF)  Maximum Capacitance (uF) 
166 V  333 V  166 V  333 V 
SQ0022  1 1  3450  860 
SQ0030  1 1  4602  1147 
SQ0045  2 1  6908  1721 
SQ0090  3 1  13786 3446 
SQ0135  5 2  20679 5161 
SQ0180  6 2  27454 6893 
SQ0270  9 3  41359 10339 
SQ0360  12 3  54908  13786 
SQ0450  14 4  67759  17214 
SQ0540  17 5  81659  20679 
Table 2-5: Capacitance range for different models- Three Phase mode 
 
2.11  SINK- Electronic Load mode – RLC programming ranges- Single phase 
Following output characteristics are applicable only for SEQUOIA model