Sequoia / Tahoe Series User Manual California Instruments
M447352-01 REV-A 19
TA0180
its own AC service. Total Line
currents are 2 x SQ0090/TA0090
its own AC service. Total peak
currents are 2 x SQ0090/TA0090
SQ0270 /
TA0270
336KVA Each SQ0090 chassis requires
its own AC service. Total Line
currents are 3 x SQ0090/TA0090
Each SQ0090 chassis requires
its own AC service. Total peak
currents are 3 x SQ0090/TA0090
SQ0360 /
TA0360
448KVA Each SQ0090 chassis requires
its own AC service. Total Line
currents are 4 x SQ0090/TA0090
Each SQ0090 chassis requires
its own AC service. Total peak
currents are 4 x SQ0090/TA0090
SQ0450 /
TA0450
560KVA Each SQ0090 chassis requires
its own AC service. Total Line
currents are 5 x SQ0090/TA0090
Each SQ0090 chassis requires
its own AC service. Total peak
currents are 5 x SQ0090/TA0090
SQ0540 /
TA0540
672KVA Each SQ0090 chassis requires
its own AC service. Total Line
currents are 6 x SQ0090/TA0090
Each SQ0090 chassis requires
its own AC service. Total peak
currents are 6 x SQ0090/TA0090
All Models
Line Voltage:
(3 phase, 3
wire + ground
(PE))
208 VLL ±10%
230 VLL ±10%
380 VLL ±10%
400 VLL ±10%
480 VLL ±10%
Line
Frequency:
50/60Hz ±5% Hz
Efficiency: 85 % (typical) depending on line and load conditions
Power Factor: 0.95 (typical) / 0.99 at full power.
Hold-Up
Time:
> 10 ms
Isolation
Voltage:
2200 VAC input to output
1350 VAC input to chassis