Sequoia / Tahoe Series User Manual California Instruments
40 M447352-01 REV-A
3.3 Mechanical Installation
The Sequoia/Tahoe Series are completely self-contained power sources. They are to be used free
standing on a solid surface. The units are fan cooled, drawing air in from the front and exhausting at the
rear. Each unit must be kept clear of obstruction with a 12” clearance on the rear and 6” clearance on both
the left and right sides of the unit. Special consideration of overall air flow characteristics and the resultant
internal heat rise must be always considered to avoid self-heating and over temperature problems.
3.4 Outline Drawings
Figure 3-2 and Figure 3-3 show the protective covers for External Sense connector and AC/DC input
and output respectively. Figure 3-4 show the outline drawings and overall dimensions for installation of
standalone model. Figure 3-12 shows the locations of rear panel connectors.
3.4.1 Rear Panel Protective Covers
Protective covers are provided for the rear panel AC input, AC/DC output, and Output Sense connectors.
They are installed to studs on the rear panel, as shown in Figure 3-2 and Figure 3-3 using #6-32 (Dia
3.51mm – 32 threads per inch) X 0.25” (height) with a maximum tightening torque of 1.1 Nm (10 lb-in).