EasyManua.ls Logo

Ametek SEQUOIA Series - Page 75

Ametek SEQUOIA Series
332 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Sequoia / Tahoe Series User Manual California Instruments
52 M447352-01 REV-A
Figure 3-9: Location of Output Terminals
Refer to Figure 3-9 for a view of the connector, Table 3-8 for the pinout and functions, and Table 3-9 for
the connector type for three phase output terminal block.
Name Type Range Function
Phase-A LINE Output
0-166/333 VAC;
0 V to ±220/440 VDC
Connection of AC/DC output
Phase-A
Phase-B LINE Output
0-166/333 VAC;
0 V to ±220/440 VDC
Connection of AC/DC output
Phase-B
Phase-C LINE Output
0-166/333 VAC;
0 V to ±220/440 VDC
Connection of AC/DC output
Phase-C
Table 3-8. AC/DC Three Phase Output Connector Pinout
Connector Type
AC/DC Output
Manufacturer Name: MARATHON
Manufacturer Part number: 1423570
Wire stripping length: 17 mm (11/16”); lug size: 10 AWG
Tightening torque: 4 Nm (35.4 lb-in);