3
≥100mm
B. Equipment storage and installation requirements.
The equipment should be stored or installed in a shady, normal temperature,
ventilated and dry place.
C. The equipment should be unload and transfer by forklift.
D.SPECIFICATIONS OF CONCRETE (See Fig. 4)
Specifications of concrete must be adhered to the specification as following.
Failure to do so may result in lift and/or vehicle falling.
1. Concrete must be thickness 100mm minimum and without reinforcing steel bars
and must be dried completely before lift installation.
2. Concrete must be in good condition and must be of test strength 210kg/cm
2
(3,000psi) minimum.
3. Floors must be level and no cracks.
E. POWER SUPPLY
The electrical source must be 3HP minimum. The source cable size must be 2.5mm²
Fig. 4
Concrete intensity must be
3000psi minimum
Fig.3