86
Surface burners applied do not require ad-
justment of primary air. A correct ame has
distinct internal cones of blue and green co-
lour. A short, humming ame or long, yellow
and smoking one, without clearly outlined
cones, shows improper quality of gas in the
household piping or a damaged or soiled bur-
ner. In order to check a ame, heat a burner
for around 10 minutes with a full ame, and
next turn the valve knob to the economical
ame position. The ame should not go out
or jump onto the nozzles.
INSTALLATION
Caution!
Adapting the appliance to a dierent
type of gas than that indicated by the
manufacturer of the cooker on the
data plate, or purchasing a cooker for
a dierent type of gas than supplied to
the house, is exclusively the responsi-
bility of the user and the tter.
Exchange of a burner
nozzle – unscrew the
nozzle with special socket
spanner No 7 and replace
with a new one according
to a type of gas (see ta-
bles).
Caution!
After adjustment is completed, place
a label indicating the type of gas to
which the cooker is now adapted.
Gas supply to surface burners is opened
and set by knobs, g A. Knobs should be
adjusted with the burner switched on and
set to the economical ame position, using
an adjustmentscrewdriver of the 2.5 mm size.
Adjustment
valve