REPAIR SAFETY INSTRUCTIONS
When working (adjusting) on the running engine, avoid touching hot and rotating parts.. During work on the running engine,
another person must be present that can easily access the emergency switch and must be in contact at all times with the
person performing the adjustment, to be able to switch off the engine immediately when necessary.
Use only prescribed makes of motor, gear and hydraulic oils and coolants.
SAFETY INSTRUCTIONS FOR WORK ON HYDRAULIC CIRCUITS
Make sure that no hydraulic circuit is under pressure before dismantling it. Hydraulic oil leaks under pressure may injure your
skin and cause a serious injury.
Mark all parts, hoses and pipes before removing them.
Do not operate hydraulic generators and hydraulic motors without oil.
There is danger of being scalded when handling hot oil.
Do not warm oil to temperatures above 160 °C - oil or its fumes may ignite.
For cleaning and wiping hydraulic parts use such textiles that do not leave lint.
When reassembling parts use hydraulic oil - not grease - as lubricants.
Clean screws and bolts carefully before installation, wash hoses and pipes and blow them off using compressed air.
Always use new packing in seals.
Fill new aggregates with hydraulic oil before installation.
Rinse hydraulic circuit after replacing the hydraulic device, clean the hydraulic tank as well.
Replace the oil filter cartridge.
Fill the hydraulic circuit with pure oil of the prescribed viscosity, but only when the engine has been stopped!
Wipe off overflow oil.
Check connections for tightness, whether they leak oil, before applying pressure to the system.
Do not adjust safety valves.
After all work has been finished, recheck all connections and replace all safety elements
After finishing the work install again all protective elements.
AFTER PUTTING THE MACHINE INTO OPERATION, CHECK
Oil level in the hydraulic tank.
Check up filling pressure in hydraulic generators in case they are replaced as well as pressure in safety valves. Carry out
the measurement at temperature of 40 °C (104 °F).