1. Introduction
Thank you for choosing Champion F-33 Series centrifuge from Ample
Scientific. Champion F-33 Series features:
Unique vortex ventilation system keeps chamber temperature cool
and preserves sample integrity
Wide-mouth design for convenient access to samples while
facilitating centrifuge cleaning and maintenance
Temperature controlled motor to extend centrifuge life expectancy
Well balanced system minimizing vibration and maximize operation
safety
2. Product Structure
3. Installation and Setup
1. Inspect centrifuge for any damages. Contact distributor for
questions regarding damages.
2. Place centrifuge on steady and leveled surface. The centrifuge
should be kept at least 300mm away from surrounding objects in a
well-ventilated environment. F-33 Series is for indoor use only.
3. Lid can be unlocked by rotating the ‘Safety Lock’ clockwise. Hold
‘Safety Lock’ in the unlocked position to open lid.
4. Make sure all eight of 15ml rotor buckets are installed in rotor.
Insert provided semi-circular cushions into buckets. Remove any
loose pieces or packing material in the centrifuge chamber.
5. Turn the Power Switch on. The Power Switch is located on the back
of the centrifuge.
6. Set ‘Timer’ for 1 minute, and ‘Speed’ to highest setting. Press ‘On’ to
start operation.
7. Make sure there is little to no vibration and the whirring sound
produced is smooth. If excessive vibration or abnormal sound
occurs, stop the centrifuge and contact distributor immediately
8. Your centrifuge is now ready to be used. Please use enclosed
‘Customer Service Card’ to register your machine. Upon registration,
you will receive a unique Product Warranty Card as your
certification of authenticity. Customers who failed to register their
purchased product may be ineligible for manufacturer’s limited 1-
year warranty.
4. Operation
1. Turn on centrifuge using power switch on the back.
2. Open centrifuge lid. Make sure there are no particles or liquid in
centrifuge chamber.
3. Make sure all eight of the 15ml rotor buckets are installed into rotor,
even if you plan to spin less than 8 tubes. Do not use buckets from
another manufacturer or substitute buckets from one centrifuge
to another*
1
.
Figure 1 - Product External Structure
Safety Lock
Clear Viewing Port
Pg | 1
Pg | 2
Speed
Control/Display
Time
Control/Display
Power Switch - on the Back of
Centrifuge
[On] Starts
Operation
[Off] Stops
Operation
Question and Answer IconNeed help?

Do you have a question about the Ample Scientific Champion F-33 Series and is the answer not in the manual?

Ample Scientific Champion F-33 Series Specifications

General IconGeneral
BrandAmple Scientific
ModelChampion F-33 Series
CategoryLaboratory Equipment
LanguageEnglish

Summary

Introduction

Key Features of Champion F-33 Series

Highlights unique vortex ventilation, wide-mouth design, temperature-controlled motor, and balanced system for optimal operation and sample integrity.

Product Structure Overview

Installation and Setup Guide

Pre-Operation Checks and Placement

Inspect for damage, place on a level surface, ensure 300mm clearance, and use in a well-ventilated indoor environment.

Rotor and Power Setup

Install all eight 15ml rotor buckets with cushions, remove packing, and turn on the power switch located on the centrifuge back.

Initial Test Run and Verification

Set timer for 1 minute, speed to highest, press 'On', and check for smooth operation with minimal vibration or sound.

Product Registration and Warranty

Register the centrifuge using the enclosed card to receive a Product Warranty Card for authenticity and warranty coverage.

Centrifuge Operation Instructions

Balancing Loads and Tube Installation

Balance loads with tubes of equal weight and size, using inserts for smaller tubes, and do not spin if tubes are hung by cap.

Operation Sequence

Close and lock lid securely, set speed and time, press 'On' to start, and press 'Off' to stop manually or wait for timer.

Safety Features During Operation

Centrifuge stops if lid is unlocked/opened during operation, and power switch should be turned off when not in use.

Maintenance and Care Guidelines

Cleaning and Tube Compatibility

Disconnect power for cleaning. Use quality tubes, never force them, and keep rotor buckets clean after use.

Regular Cleaning and Disinfection

Clean spills immediately. Use mild solutions. Rotor and buckets withstand up to 120°C for sterilization but do not autoclave.

Optimal Storage Conditions

Store in ambient temperature (0-30°C), low relative humidity (≤30%), and an atmosphere clear of dusts, gas, and corrosives.

Prohibited Usage and Warnings

Environmental and Operational Restrictions

Do not store/use in unspecified conditions, let unqualified persons operate, or operate without proper rotor/bucket installation.

Material and Chemical Restrictions

Do not overload, use damaged parts, use non-original accessories, or use chemicals causing damage or corrosion.

Hazardous Medium and Environment

Do not centrifuge flammable or explosive medium, or operate near explosive materials.