INTERNAL WALL
24"
16" MINIMUM
FOR STEAM HOSE
FAN
PACK
STEAM
HUMIDIFIER
DRAIN
GROW
LIGHT
GROW
LIGHT
2 FEET
MINIMUM TO
SIDE WALL
1-1/2 FEET
MINIMUM TO CEILING
ALLOW A
3 TO 5 FOOT
PATH FOR THE
STEAM TO DISSIPATE
DEPENDING ON
TEMPERATURE
AS35FP Steam Humidifier
Quick Start Guide
Choose a location in a
conditioned space
Install drain line
Secure 7/8" drain line with the hose clamp provided. Do not over tighten.
Make sure drain line has a constant downward slope and is not kinked
or blocked.
If floor drain is not available, use condensate pump to route water to a drain.
NOTE: The humidifier uses cold water to temper drain water to less than 140°F.
1
3
90-2196
Fan pack location
The fan pack has a set fan speed, the fan blows
over the steam outlet to help the steam absorb
into the surrounding air. See the figure above for
placement guidance. Install the fan pack such that
steam is dispersed above canopy height.
2
1