Table of Contents

Question and Answer IconNeed help?

Do you have a question about the AngioDynamics NanoKnife and is the answer not in the manual?

AngioDynamics NanoKnife Specifications

General IconGeneral
BrandAngioDynamics
ModelNanoKnife
CategoryMedical Equipment
LanguageEnglish

Summary

NanoKnife Safety Instructions

Generator Safety Features

Details safety features like output current restriction, double trigger foot pedal, and test pulse.

Key NanoKnife Warnings

Highlights potential risks, including arrhythmia, electrode hazards, and electrocution.

Arrhythmia Risk Considerations

Details risks related to patient Q-T intervals, energy delivery, and synchronization devices.

Safe Handling of Electrodes

Covers safe handling, sterility, expiration dates, and electrical separation of electrodes.

Electrocution Hazard Warnings

Warns about high internal voltages, grounding requirements, and avoiding flammable mixtures.

NanoKnife System Components

NanoKnife Installation and Start-Up

Generator Start-Up and Warm-Up Procedure

Outlines the step-by-step process for starting up and warming up the Generator, including self-checks.

NanoKnife System Operation Guide

Information Screen Details

Details the Information screen sections: Patient, Case, Clinical Data, and Institution.

Probe Selection Screen Guide

Explains how to select probe types, views, and connection status for ablation.

Probe Placement Process Screen

Covers defining ablation parameters, probe placement, and settings on the grid.

Pulse Generation Screen Operation

Describes the screen for delivering ablation, including procedure parameters and result graphs.

Ablation Delivery Procedure

Details the steps for delivering ablation, including test pulses, arming, and starting the procedure.

Emergency Procedure Interruption

Explains how to interrupt or stop a procedure using the Abort button or Red STOP button.

External ECG Synchronization

External R-Wave Detector Specifications

Specifies the requirements and specifications for an external R-wave detector.

NanoKnife Troubleshooting Guide

Documented Problems and Solutions

Lists common malfunctions, their possible reasons, and recommended actions.

NanoKnife Error Messages

Details various error messages, their possible causes, and corrective actions.

NanoKnife Maintenance and Service

Preventive Maintenance Schedule

Outlines recommended checks and maintenance schedule, including annual service.