3.0 INSTALLATION
When facing the pump, the roller assembly spins in a clockwise direction. The inlet (suction) side is
located on the left side of the pump head, and the outlet (discharge) is located on the right.
Mount the pump in a level, dry location close to the injection point. To minimize back-pressure on
the system, keep the discharge tubing a short as possible.
The recommended location is above the height of the solution tank. Mounting the pump lower than
the solution tank will gravity feed the solution and create a “ooded suctioninstallation. In this
scenario, a shut-off valve or other device must be installed to stop the solution ow to the pump
during pump servicing.
In installations involving pressure, a check valve should be used at the point of injection to prevent
potential back-ow.
Do not mount pump directly over an open solution tank as chemical fumes may damage the pump.
Voltage and frequency of power supply must be the same as shown on unit specication label.
Ambient air temperature should not exceed 104° F (40° C) and adequate air ow should be provided.