3.0 INSTALLATION
• When facing the pump, the roller assembly spins in a clockwise direction. The inlet (suction) side is
located on the left side of the pump head, and the outlet (discharge) is located on the right.
• Mount the pump in a level, dry location close to the injection point. To minimize back-pressure on
the system, keep the discharge tubing a short as possible.
• The recommended location is above the height of the solution tank. Mounting the pump lower than
the solution tank will gravity feed the solution and create a “ooded suction” installation. In this
scenario, a shut-off valve or other device must be installed to stop the solution ow to the pump
during pump servicing.
• In installations involving pressure, a check valve should be used at the point of injection to prevent
potential back-ow.
• Do not mount pump directly over an open solution tank as chemical fumes may damage the pump.
• Voltage and frequency of power supply must be the same as shown on unit specication label.
• Ambient air temperature should not exceed 104° F (40° C) and adequate air ow should be provided.