Operating voltage
voltage range
Allowable operating
Rated frequency
Contact rating
Status Indicator
Power consumption
Life
Ambient temperature
Ambient humidity
Weight
Mechanical : 5,000,000 times / Electrical : 100,000 times
85 ~ 110% of rated operating voltage
50 / 60 Hz
POWER - Red / RELAY ON - Green
240VAC 7A(N.O.), 240VAC 5A(N.C.) Resistive load
Approx. 3.3VA
-10 ~ +50
o
C
MAX 85% RH
Approx. 170g
AC/DC : 12 ~ 48V / AC/DC : 100 ~ 240V
APT-8S / APT-9S
WEEKLY PROGRAMMABLE TIMER
User's Manual
User's Manual
BUTTON and SWITCH FUNCTIONSSPECIFICATIONS
OPERATING FLOWCHART
DAY
DAY
: Day of Week Setup
HR
HR
: Hour Setup
MIN
MIN
: Minute Setup
SEC
SEC
: Second Setup
PROG.
PROG.
: Program Selection
MODE
MODE
: Mode Selection
START
START
: Start Mode
CLEAR
CLEAR
: Clear Setting
12/24H
12/24H
: 12H or 24H
+1H
+1H
: Daylight-Saving-Time
MAN
MAN
: Manual Override
RESET
RESET
: Program Reset
TIMER
TIMER
: Timer Control
min
min
: Twin Timer Unit - Hr : Min
PULSE
PULSE
: Pulse Output
sec
sec
: Twin Timer Unit - Min : Sec
ON
ON
: Power / Battery On
OFF
OFF
: Power / Battery Off
Set Daylight-Saving-Time
Manual ON or OFF
(Override Current Program)
Manual ON or OFF
(Override all Programs)
Start
+1H MAN MAN
Set 12H OR 24H
12/24H
Set Day of Week Set Hour
Set Minute Program Enable Or Disable Start Mode
Pulse Setting Set Program Number
PROG.
Set Pulse Width (Second)
SEC HR
MIN CLEAR START
Switch to PROGRAM MODE
MODE
Switch to START MODE
MODE
Set Hour
OR
Set Minute
(
APT-9S only
APT-9S only
)
Start Clearing EEPROM
(
APT-9S only
APT-9S only
)
Clearing EEPROM
(
APT-9S only
APT-9S only
)
EEPROM Cleared
Clock Setting
HR MIN CLEAR
Set Day of Week
DAY
MO
MO TU WE TH FR SASU TU TU TU
S
T
E
TU
RESET
OFF
BAT.
ON
5S
3S
MO
CLK
AM
PM
MO
CLK
MO
CLK
1h
+
ON OFF
MO
CLK
ON OFF
MO
CLK
S
T
E
S
T
E
ON
MO
S
T
E
ON
MO TU WE TH FR SASU
S
T
E
ON
MO TU
S
T
E
ON
MO TU
S
T
E
ON
MO TU
S
T
E
MO
CLK
MANDAY
DAY
For APT-9S
For APT-8S
Set Day of Week Set Hour Set Minute
Program Enable Or Disable Start Mode
Timer Setting
HR MIN PROG.
CLEAR START
ON
MO TU WE TH FR SASU
S
T
E
ON
TU
S
T
E
ON
TU
S
T
E
Set Hour Set Minute
HR MIN
OFF
TU
S
T
E
OFF
TU
S
T
E
OFF
TU
S
T
E
MO
CLK
TIMER
PULSE
TIMER
PULSE
ON
MO
S
T
E
Set OFF Time
OFF
TU
S
T
E
Example :
A machine is turned on at 8:00 AM and turned off at 5:00 PM, from Monday to Friday. In addition, the machine is turned on between
9:00 AM and 11:00 AM on Saturday for inspection. The correct setting is as followed:
Timer Output
PROGRAM MODE
START MODE
CLOCK MODE
(Day and Time are flashing under this mode.)
Pulse Output
OFF
AM
SA
S
T
E
ON
AM
SA
S
T
E
OFF
PM
MO TU WE TH FR
S
T
E
ON
AM
MO TU WE TH FR
S
T
E
TU
1
2
3
MANDAY
DAY
For APT-9S
For APT-8S
SAFETY PRECAUTION
SAFETY PRECAUTION
This manual uses the following symbols to ensure safe operation of this timer.
WARNING
WARNING
CAUTION
CAUTION
Warnings are indicated when mishandling this controller might result in death or serious injury
Cautions are indicated when mishandling this controller might result in minor injury to the user,
to user.
or only physical damage to the timer.
Note this incorrect wiring of this controller can damage it and lead to other hazards. Make sure the controller has
been correctly wired before turning the power ON.
Before wiring, or removing / mounting the controller, be sure to turn the power OFF. Failure to do so might cause
electric shock.
Do not touch electrically charged parts such as the power terminals. Doing so might cause electric shock.
Do not disassemble the controller. Doing so might cause electric shock or faulty operation.
Use the controller within the operating ranges recommended in the specification (temperature, humidity, voltage,
shock, mounting direction, atmosphere and etc.). Failure to do so might cause fire or faulty operation.
Firmly tighten the terminal screws. Insufficient tightening of terminal screws might cause electric shock or fire.
Press reset before use after turning the battery on or replace the battery.
WARNING
CAUTION
When using this product in applications
that require particular safety or when
using this product in important facilities,
please pay attention to the safety of the
overall system and equipment. Install fail-
safe mechanisms, perform redundancy
checks and periodic inspections and
adopt other appropriate safety measures
when it is necessary. This product is rated
at Class .
RESTRICTIONS ON USE
LOAD
SOURCE
LOAD LOAD
SOURCE
LN
SOURCE
LN
Question and Answer IconNeed help?

Do you have a question about the Anly APT-8S and is the answer not in the manual?

Anly APT-8S Specifications

General IconGeneral
TypeDigital Timer
DisplayLCD
Timer Resolution1 second
Battery BackupYes
Input Voltage100-240V AC
OutputRelay

Summary

Safety Precautions

General Warnings and Cautions

Safety warnings and cautions for potential hazards during operation and handling.

Specific Safety Notes

Important safety instructions regarding wiring, power, touching charged parts, and disassembly.

Product Specifications

Button and Switch Functions

Operating Modes and Features

Clock Mode Setup

Setting the current time and day of the week.

Start Mode Setup

Setting the timer's start mode and daylight-saving time.

Program Mode Setup

Configuring timer output and pulse output schedules.

Holiday Suspension Mode

Temporarily suspending programs for holidays.

Twin Timer Mode

Setting up dual timer units for specific timing intervals.

Power Backup Feature

Retaining clock and program memory during power interruptions.

Connection and Conversion

Wiring Connections

Illustrates wiring configurations for separate and shared power sources.

Mounting Type Conversion

Instructions for converting between flush and surface mounting types.

Related product manuals