Anly H5CLR-8 User Manual

Default Icon
2 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
RESET
s
GATE
RUN
OUT
K/P
h
RESET
m
START
H5CLR
TIMER
Operating voltage
Allowable operating
voltage range
Rated frequency
Contact rating
Reset time
Power consumption
Life
Ambient temperature
Ambient humidity
Weight
Mechanical : 5,000,000 times / Electrical : 100,000 times
85 ~ 110% of rated operating voltage
50 / 60Hz
MAX 0.1s
250VAC 5A (Resistive load)
Approx. 2.5VA
-10Д+50°C
MAX 85% RH
Approx. 120g(H5CLR) / 150g(ASY-4DR)
AC/DC : 12Д48V / AC/DC : 100Д240V
NAMES AND FUNCTIONS OF FACEPLATESPECIFICATIONS
SETTING PROCEDURE
CONNECTION
Product is subject to change without notice.
Upper display
Display PV values (current time, etc.) or
setup items.
Lower display
Display SV values (set time, etc.) and
other parameter values.
key :
Used for incrementing or decrementing
numeric values.
Performing arithmetic shift operations and
switches the display. Hold down for at least
3 seconds to enter setting modes.
LEDs
RUN: Timing indicator
OUT: Control output indicator
K/P: Key protection indicator
RESET: Reset indicator
START: Start indicator
GATE: Gate indicator
h: Time unit display (Hour)
m: Time unit display (Minute)
s: Time unit display (Second)
key :
Reset the output or save the value
of setting.(after save than back to
the operation mode)
key :
RESET
POWER ON or
RESET
Reset
SPECIAL FUNCTION KEY
TIME RANGE
9.999s
Select the
time range
Switch to output
setting mode
OUTPUT MODE
Select
output mode
Switch to count up/down
setting mode
UP / DOWN MODE
Select count up
or count down
Switch to input signal
time setting mode
INPUT SIGNAL TIME
Select input
signal time
ϡ Mode A1,A2,A3,B1,B2,C,D and F are not available on ASY-4DRϭ and H5CLR-8
OUTPUT TIME
Select
output time
ϡ Not functionable on MODE C,D,E and F
ϡ Not available for ASY-4DRϭ and H5CLR-8
Switch to key protection level
setting mode
KEY PROTECTION LEVEL
Select key
protection level
Switch to output contact
setting mode
OUTPUT CONTACT
Select output
contact
ϡ Available on H5CLR-8/-11 and ASY-4DRϭʳtype only
Switch to time range
setting mode
H5CLR-8 & ASY-4DRϭ H5CLR-8G & ASY-4DRGϭ H5CLR-11 H5CLR-11M H5CLR-11MI
H5CLR / ASY- 4DR
MULTI-FUNCTION DIGITAL TIMER
User's Manual
SAFETY PRECAUTION
This manual uses the following symbols to ensure safe operation of this timer.
WARNING
CAUTION
Warnings are indicated when mishandling this product might result in death or serious injury
Cautions are indicated when mishandling this product might result in minor injury to the user,
to user.
or only physical damage to the timer.
ΘNote this incorrect wiring of this product can damage it and lead to other hazards. Make sure the product has
been correctly wired before turning the power ON.
ΘBefore wiring, or removing / mounting the product, be sure to turn the power OFF. Failure to do so might cause
electric shock.
ΘDo not touch electrically charged parts such as the power terminals. Doing so might cause electric shock.
ΘDo not disassemble the product. Doing so might cause electric shock or faulty operation.
ΘUse the product within the operating ranges recommended in the specification (temperature, humidity, voltage,
shock, mounting direction, atmosphere and etc.). Failure to do so might cause fire or faulty operation.
ΘFirmly tighten the wires to the socket. Insufficient tightening of the wires to the socket might cause fire.
WARNING
CAUTION
RESET
99.99s
999.9s
Count up
Count down
9999s
999.9m
9999m
999.9h
9999h
99m59s
99h59m
Hold
0.1s
20ms
1ms
0.5s
1s
5s
10s
15s
20s
Mode A
Mode A1
Mode A2
Mode A3
Lock function key
Lock reset key
2C
1A1C
Lock preset value key
Lock all key
Mode B
Mode B1
Mode B2
Mode C
Mode D
Mode E
Mode F
See reverse page for more details
Switch ON / OFF Key
protection
PRESS FOR 3s PRESS FOR 3s
Switch to input setting mode
RESET
Switch to input setting mode
(1)Stop (2)Timing
PRESS
FOR 3s
PRESS
FOR 3s
or
Switch to input setting mode
RESET
RESET
Save and back to the
operation mode
or
RESET
Save and back to the
operation mode
or
RESET
Save and back to the
operation mode
or
RESET
Save and back to the
operation mode
or
RESET
Save and back to the
operation mode
or
RESET
Save and back to the
operation mode
or
Switch to output time
setting mode
RESET
Save and back to the
operation mode
or
K / P : Key Protection
PNP type
K / P : Key Protection
NPN type
When using this product in applications
that require particular safety or when
using this product in important facilities,
please pay attention to the safety of the
overall system and equipment. Install fail-
safe mechanisms, perform redundancy
checks and periodic inspections and
adopt other appropriate safety measures
when it is necessary. This product is rated
at Class .
RESTRICTIONS ON USE
SOURCE
3
2
1
8
9
10
11
7
6
5
4
START
GATE
K / P
RESET
(Sensor)
+12VDC(50 mA)
Load
(-)(+)
NL
3
2
1
8
9
10
11
7
6
5
4
START
GATE
K / P
(Sensor)
Common (0V)
12 VDC(50 mA)
Load
(-) (+)
RESET
SOURCE
NL
3
2
1
8
9
10
11
7
6
5
4
T.D. INST.
RESET
START
SOURCE
NL
4
3
2
18
7
6
5
RESET
START
SOURCE
NL
T.D. INST.
4
3
2
18
7
6
5
SOURCE
NL
Question and Answer IconNeed help?

Do you have a question about the Anly H5CLR-8 and is the answer not in the manual?

Anly H5CLR-8 Specifications

General IconGeneral
BrandAnly
ModelH5CLR-8
CategoryTimer
LanguageEnglish