TIMING CHART(Output mode)
DIMENSION(mm)
Printed in Taiwan
M-H5CLR-I-A
ANLY ELECTRONICS CO., LTD.
http://www.anly.com.tw
ASY-4DRN / ASY-4DRGN ASY-4DRY / ASY-4DRGY + US-08
H5CLR H5CLR + Y-50 + US-08
A : Signal ON delay 1 (Timer resets when power comes ON.)
A-1 : Signal ON delay 2 (Timer resets when power comes ON.)
A-2 : Power ON delay 1 (Timer resets when power comes ON.)
A-3 : Power ON delay 2 (Timer dose not reset when power comes ON.)
B-1 : Repeat cycle 2 (Timer dose not reset when power comes ON.)
B : Repeat cycle 1 (Timer resets when power comes ON.)
F : Cumulative (Timer does not reset when power comes ON.)
E : Interval (Timer resets when power comes ON.)
B-2 : Repeat cycle ON start (Timer resets when power comes ON.)
C : Signal ON/OFF delay (Timer resets when power comes ON.)
D : Signal OFF delay (Timer resets when power comes ON.)
45
+0.5
-0
45
+0.5
-0
RESET
h
m
s
RESET
START
GATE
RUN
OUT
K/P
ASY-4DR
ANLY ELECTRONICS CO.
RESET
h
m
s
RESET
START
GATE
RUN
OUT
K/P
ASY-4DR
ANLY ELECTRONICS CO.
45
+0.5
-0
45
+0.5
-0
Timing starts when the start signal goes ON. *Note1
The control output is controlled using a sustained or
one-shot time period.
Timing starts when the reset input goes OFF.
The start signal disables the timing function (ie., same
function as the gate input).
The control output is controlled using a sustained or
one-shot time period.
Timing starts when the reset input goes OFF.
The start signal disables the timing function (ie., same
function as the gate input).
The control output is controlled using a sustained or
one-shot time period.
Timing starts when the start signal goes ON. *Note1
The status of the control output is reversed when time is up
(OFF at start).
Timing starts when the start signal goes ON. *Note1
The status of the control output is reversed when time is up
(OFF at start).
Timing starts when the start signal goes ON. *Note1
The status of the control output is reversed when time
is up (OFF at start).
Timing starts when the start signal goes ON or OFF.
The status of the control output is ON when the start
signal goes ON or OFF.
The control output is ON when the start signal is ON
(except when the power is OFF or the reset is ON).
The timer is reset when the time is up.
Timing starts when the start signal comes ON. *Note1
The control output is reset when time is up.
Start signal enables timing (timing is stopped when the start
signal is OFF or when the power is OFF)
A sustained control output is used.
Timing starts when the start signal goes ON, and is reset
when the start signal goes OFF. *Note1
The control output is controlled using a sustained or one-
shot time period.
*Note1. While the start signal is ON, the timer starts when power
comes ON or when the reset input goes OFF.
SOURCE
Start signal
Gate
Reset
Control output
Set value
0
Set value
0
UP
DOWN
tt
SOURCE
Start signal
Gate
Reset
Control output
Set value
0
Set value
0
UP
DOWN
t
SOURCE
Start signal
Gate
Reset
Control output
Set value
0
Set value
0
UP
DOWN
t t a t - a
SOURCE
Start signal
Gate
Reset
Control output
Set value
0
Set value
0
UP
DOWN
t
SOURCE
Start signal
Gate
Reset
Control output
Set value
0
Set value
0
UP
DOWN
SOURCE
Start signal
Gate
Reset
Control output
Set value
0
Set value
0
UP
DOWN
SOURCE
Start signal
Gate
Reset
Control output
Set value
0
Set value
0
UP
DOWN
SOURCE
Start signal
Gate
Reset
Control output
Set value
0
Set value
0
UP
DOWN
SOURCE
Start signal
Gate
Reset
Control output
Set value
0
Set value
0
UP
DOWN
UP
DOWN
SOURCE
Start signal
Reset
Control output
Set value
0
Set value
0
UP
DOWN
SOURCE
Start signal
Reset
Control output
Set value
0
Set value
0