EN
101
ANSLUT 416121
Low Temperature heat pump
Equipped with a supplementary
heater
Heat pump combination heater
Parameters shall be declared for medium temperature application, except for low temperature heat pumps. For low temperature heat pumps,
parameters shall be declared for low-temperature application
Parameters shall be declared for average climate conditions
Item Symbol Value Unit Item Symbol Value Unit
Rated Heat Output(³) Prated 3.26 kW Seasonal space heating energy
efficiency
Ƞs 125 %
Declared capacity for heating for part load at indoor temperature 20°C
and outdoor temperature Tj
Declared capacity for heating for part load at indoor temperature 20°C
and outdoor temperature Tj
Tj = - 7 Pdh 2.72 kW Tj = - 7
2.28 - or %
Tj = + 2 Pdh 2.72 kW Tj = + 2
2.84 - or %
Tj = + 7 Pdh 2.44 kW Tj = + 7
4.45 - or %
Tj = + 12 Pdh 2.83 kW Tj = + 12
5.72 - or %
Tj = bivalent temperature Pdh 2.76 kW Tj = bivalent temperature
2.39 - or %
Tj = operation limit temperature Pdh 2.21 kW Tj = operation limit temperature
PERd
1.92
- or %
For air-to-water heat pumps: Tj = -
15°C (if TOL<-20°C)
Pdh kW For air-to-water heat pumps: Tj = -
15°C (if TOL<-20°C)
PERd
- or %
Bivalent Temperature Tbiv -6 °C For air-to-water heat pumps:
Operating limit temperature
TOL -10 °C
Cycling interval capacity for heating Pcych kW Cycling interval efficiency
- or %
Degradation co-efficient Cdh 1.0 - Heating water operating limit
temperature
WTOL 52 °C
Power Consumption in modes other than active mode Supplementary heater
Off Mode POFF
0.013
kW Rated heat output Psup 1.05 kW
Thermostat off mode PTO
0.040
kW
Electricity
Standby mode PSB
0.014
kW Type of energy input
Crankcase heater mode PCK
0.033
kW
Other Items Inverter
Capacity Control Variable For air-to-water heat pumps: Rated
air flow, outdoors
- 1750 m³/h
Sound power level, indoor/outdoor LWA 42/ 62 dB For water- or brine-to-water heat
pumps: Rated brine or water flow
rate, outdoor heat exchanger
- m³/h
Annual energy consumption QHE 2122 kWh
For heat pump combination heater
Declared load profile Water heating energy efficiency Ƞwh %
Daily Electricity consumption Qelec kWh Daily fuel consumption Qfuel kWh
Annual electrical consumption AEC kWh Annual fuel consumption AFC GJ
(³) For heat pump space heaters and heat pump combination heaters, the rated heat output Prated is equal to the design load for heating Pdesignh,
and the rated heat output of a supplementary heater Psup is equal to the supplementary capacity for heating sup(Tj).
(⁴) If Cdh is not determined by measurement the the default degradation coefficient is Cdh = 0.9