PAGE 2
IN CASE OF FIRE: Manual Actuation
PUSH RED BUTTON FOR
IMMEDIATE ACTIVATION
OPEN
GUARD DOOR
009343
1) Safely bring equipment to complete stop, set brake and
shut off engine.
2) Break visual seal and open guard door.
3) Push the red “PUSH To Activate / Alarm When Lit” button.
4) Release circuit immediately activates the connected fire
suppression system (if included, pressure switch activates
auxiliary operation). See Note below.
5) Safely exit equipment and stand-by with supplemental
firefighting equipment.
6) Optional manual actuation: Pull ring pin and strike red
button on electric or pneumatic manual actuator.
Note: The red “PUSH To Activate / Alarm When Lit” LED and
sounder remain steady-on for 10 sec. during initiation (release)
of fire suppression system. Post release: Detection 1 and/or
Detection 2, Shutdown, and Release LEDs and sounder
continue to pulse 1 x 10 sec. If safe to re-enter equipment,
push “DELAY/Reset/Silence” button to silence sounder for two
hours.
Electric or Pneumatic Manual Actuator Location(s):
Fill-In System Information (as installed)

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ansul CHECKFIRE 210 and is the answer not in the manual?

Ansul CHECKFIRE 210 Specifications

General IconGeneral
BrandAnsul
ModelCHECKFIRE 210
CategorySecurity Sensors
LanguageEnglish

Related product manuals