7. MAINTENANCE
NOTE :
These operations necessitate special tools and skills and must be done at authorized service stations.
EVERY 500 HOURS
Check valve-rocker arm
clearances and adjust if
necessary.
Valve clearance (cold
engine) :
0,15 - 0,20 mm
Check injector nozzle
opening pressure and
adjust if necessary.
Injector nozzle opening
pressure :
190 - 200 kg/cm