High Resolution Digital Crane Scale User Guide
Page 10 of 12
approximately12hours.
Toobtainmaximumservicelife,batteryshouldbestored
between‐20
(4
°
F)and+50
(122
°
F).Storedbatteriesshould
berechargedeverythreemonths.
Duringcharging,greenLEDindicatesfullofpower,whilered
indicatesthatchargingisgoingon.
10.
Troubleshooting
Simpleproblemscanberesolvedasbelowlistedsolution.If
problemsstillexist,pleasecontactyourlocalrepresentative.
Symptom PossibleCause SuggestedSolution
notpoweron
afterOn/Off
ispressed
discharged/
defectivebattery
checkbatteryand
charge
defectiveOn/Off
key
pressharderandkeep
pressing2s
defectivepower
cable
openfrontpanel,
checkpowercable
defective
mainboard
contactrepresentative
display
flashes
dischargedbattery chargebattery
noaction
takenafter
keypressed
scaleisdisturbed replugpowercable
defectivekey contactrepresentative
weight
readingnot
stable
loadinmotion keeploadstable
weakAntiMotion
changeAntiMotion
level
dampedloadcellor dryloadcellor